Suppr超能文献

锝-99m 乙二巯基丁二酸和锝-99m 二巯基丁二酸闪烁扫描术——两者在检测瘢痕形成和鉴别皮质功能方面的比较

Tc-99m Ethylenedicysteine and Tc-99m Dimercaptosuccinic Acid Scintigraphy-Comparison of the Two for Detection of Scarring and Differential Cortical Function.

作者信息

Dharmalingam Anitha, Pawar Shwetal U, Parelkar Sandesh V, Shetye Suruchi S, Ghorpade Mangala K, Tilve Gundu H

机构信息

Department of Nuclear Medicine Surgery, Seth G S Medical College and KEM Hospital, Parel, Mumbai, India.

Department of Pediatric Surgery, Seth G S Medical College and KEM Hospital, Parel, Mumbai, India.

出版信息

Indian J Nucl Med. 2017 Apr-Jun;32(2):93-97. doi: 10.4103/0972-3919.202240.

Abstract

CONTEXT

The differential cortical function obtained by Tc-99m EC is comparable to that of Tc-99m DMSA. However, identification of scars on Tc-99m EC images needs to be studied.

AIMS

The aim of the study is to evaluate role of Tc-99m EC for detection of scarring and differential cortical function by comparing with Tc-99m DMSA.

SETTINGS AND DESIGN

Prospective observational study of recurrent UTI; minimum 6 weeks after acute episode; when urine examination is negative for pus cells.

MATERIALS AND METHODS

Forty-seven children with normal positioned kidneys underwent Tc-99m EC and DMSA scintigraphy. The DRF and cortical phase images of both studies in the same image matrix size were evaluated by two independent observers for scarring; Tc-99m DMSA was considered as the gold standard.

STATISTICAL ANALYSIS USED

MS Excel 2007 and GraphPad Instat V3.1 and ROC analysis.

RESULTS

There was no significant difference in the detection of scarring using two studies with Cohen's kappa coefficient (κ) 0.932. The sensitivity and specificity of Tc-99m EC for detection of scarring was 98.75% and 99.15%, respectively. There was good agreement between the differential cortical function calculated using two studies.

CONCLUSIONS

The summed Tc-99m EC images with an acceptable high image contrast allow detection of cortical scarring in patients with normal kidney positions. It is an excellent single-modality comprehensive investigational agent for renal parenchymal defects, function, and excretion evaluation with the added advantages of lower cost, convenience, and low radiation exposure to the child.

摘要

背景

锝-99m依替菲宁(Tc-99m EC)获得的皮质功能差异与锝-99m二巯丁二酸(Tc-99m DMSA)相当。然而,在Tc-99m EC图像上识别瘢痕仍需进一步研究。

目的

本研究旨在通过与Tc-99m DMSA比较,评估Tc-99m EC在检测瘢痕和皮质功能差异方面的作用。

设置与设计

复发性尿路感染的前瞻性观察研究;急性发作后至少6周;尿检查脓细胞阴性时。

材料与方法

47例肾脏位置正常的儿童接受了Tc-99m EC和DMSA闪烁扫描。由两名独立观察者对相同图像矩阵大小的两项研究的肾动态功能(DRF)和皮质期图像进行瘢痕评估;Tc-99m DMSA被视为金标准。

所用统计分析方法

MS Excel 2007、GraphPad Instat V3.1和ROC分析。

结果

两项研究在瘢痕检测方面无显著差异,科恩kappa系数(κ)为0.932。Tc-99m EC检测瘢痕的敏感性和特异性分别为98.75%和99.15%。两项研究计算的皮质功能差异之间具有良好的一致性。

结论

Tc-99m EC图像对比度高,可接受,能检测出肾脏位置正常患者的皮质瘢痕。它是一种优秀的单模态综合检查剂,用于评估肾实质缺损、功能和排泄,具有成本低、方便、儿童辐射暴露低等优点。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c8ab/5439197/3c8fc6d743b1/IJNM-32-93-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验