[采用全身与节段生物电阻抗测量(BIS)评估电阻(Re)和细胞外液量(ECV)以确定接受血液透析治疗的终末期肾病患者的干体重]

[Whole body versus segmental bioimpedance measurements (BIS) of electrical resistance (Re) and extracellular volume (ECV) for assessment of dry weight in end-stage renal patients treated by hemodialysis].

作者信息

Załuska Wojciech, Małecka Teresa, Mozul Sławomir, Ksiazek Andrzej

机构信息

Katedra i Klinika Nefrologii, Akademii Medycznej w Lublinie.

出版信息

Przegl Lek. 2004;61(2):70-3.

Abstract

The precise estimation of the hydration status of the human body has a great meaning in the assessment of dry weight in end-stage renal disease patients treated by hemodialysis. The bioimpedance technique (BIS) is postulated as easy in use and as a non-invasive method in monitoring the size of hydrate space such as total body water (TBW) and extracellular volume (ECV). However, the precision of the method (Whole Body Bioimpedance Technique) has been questioned in several research papers. One of the problems lies in fluid transfer from peripheral spaces (limbs) to the central space (trunk) while changing the position of the body (orthostatic effect). This phenomena can be eliminated using segmental bioimpedance technique (4200 Hydra, Analyzer, Xitron, San Diego, CA, U.S.A.). The purpose of the study was to estimate the changes of electrical resistance (Re) the extracellular volume (ECV) at the time -pre, and -post 10 hemodialysis sessions using whole body bioimpedance technique (WBIS) in comparison to BIS measurements in specific segments of the body; arm (ECVarm), leg (ECVleg), trunk (ECVtrunk). The sum of changes in extracellular volume (ECV) in segments (2ECVarm+ ECVtrunk + 2ECVleg) was 13.26 +/- 1.861 L in comparison to 17.29 +/- 2.07 L (p < 0.01) as measured by WBIS technique at the time before HD. The changes in electrical resistance Re was of 558 +/- 68 W as calculated from the sum of segments versus 560 +/- 70 W (p < 0.05) as measured by WBIS. At the time after hemodialysis the sum of segmental ECV volume measurement was of 11.42 +/- 1.28 L in comparison to 14.84 +/- 1.31 (p < 0.001) from WBIS the whole body technique (WBIS) and changes in electrical resistance Re was of 674 +/- 67 W as calculated from the sum of segments versus 677 +/- 64 (p < 0.05) W respectively. The observed difference between the identical electrical resistance Re as measured by WBIS in comparison to the sum of segment measurements and important difference between ECV volume as measured by WBIS versus sum of segment ECV measurements can be partly explain by non-cylindric nature of human body composition. However, the segmental bio-impedance technique is a method which gives us more accurate data about the extracellular volume taken from each segment in the hemodialysis patient but the accuracy of trunk water assessment is still a problem.

摘要

精确评估人体的水合状态对于评估接受血液透析治疗的终末期肾病患者的干体重具有重要意义。生物电阻抗技术(BIS)被认为使用简便,是一种监测水合空间大小(如总体水(TBW)和细胞外液量(ECV))的非侵入性方法。然而,该方法(全身生物电阻抗技术)的精度在几篇研究论文中受到了质疑。其中一个问题在于身体位置改变时(直立位效应),液体从外周空间(肢体)转移到中央空间(躯干)。使用分段生物电阻抗技术(美国加利福尼亚州圣地亚哥市Xitron公司的4200 Hydra分析仪)可以消除这种现象。本研究的目的是使用全身生物电阻抗技术(WBIS)估计10次血液透析治疗前后人体电阻(Re)和细胞外液量(ECV)的变化,并与身体特定部位(手臂(ECVarm)、腿部(ECVleg)、躯干(ECVtrunk))的BIS测量结果进行比较。与血液透析前WBIS技术测量的17.29±2.07 L相比,各部位细胞外液量变化之和(2ECVarm + ECVtrunk + 2ECVleg)为13.26±1.861 L(p<0.01)。根据各部位测量值计算得出的电阻Re变化为558±68Ω,而WBIS测量值为560±70Ω(p<0.05)。血液透析后,各部位ECV体积测量值之和为11.42±1.28 L,而全身技术(WBIS)测量值为14.84±1.31 L(p<0.001),电阻Re变化根据各部位测量值计算为674±67Ω,而WBIS测量值为677±64Ω(p<0.05)。WBIS测量的相同电阻Re与各部位测量值之和之间观察到的差异,以及WBIS测量的ECV体积与各部位ECV测量值之和之间的显著差异,部分可以由人体成分的非圆柱形性质来解释。然而,分段生物电阻抗技术是一种能为我们提供血液透析患者各部位更准确细胞外液量数据的方法,但躯干水评估的准确性仍然是一个问题。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验