Qiu Hai-Bo, Xu Hong-Yang, Yang Yi, Zhou Shao-Xia, Chen Yong-Ming, Sun Hui-Ming
Department of Critical Care Medicine, Zhongda Hospital and School of Clinical Medicine, Southeast University, Nanjing 210009, Jiangsu, China.
Zhongguo Wei Zhong Bing Ji Jiu Yi Xue. 2004 Jul;16(7):399-402.
To access alveolar recruitment with positive end-expiratory pressure (PEEP) and to correlate the recruited volume with arterial oxygenation in acute respiratory distress syndrome (ARDS).
Eleven ventilated patients satisfying criteria of ARDS were included in the study group. Recruited volume of three different PEEP levels [5 cm H2O, 10 cm H2O, 15 cm H2O (1 cm H2O=0.098 kPa)] were measured by pressure-volume curve method. Effects of different PEEP levels on lung mechanics and gas exchange were compared.
Lung recruited volume elevated when PEEP increased from 5 cm H2O to 15 cm H2O[(40.2+/-15.3)ml vs. (123.8+/-43.1)ml vs. (178.9+/-43.5)ml, all P<0.05]. Arterial oxygenation index increased with PEEP and a positive correlation was found between recruited volume and changes in arterial oxygenation index (r=0.483, P<0.01). There was no significant difference during the static compliance at different PEEP levels at a fixed tidal volume (P>0.05). Recruited volume at PEEP 15 cm H2O in the patient group with lower inflection point (LIP) was larger than the group without LIP.
Recruited volume increases with PEEP, and the PEEP-induced increase in arterial oxygenation is significantly correlated to recruited volume.
评估急性呼吸窘迫综合征(ARDS)患者使用呼气末正压(PEEP)时的肺泡复张情况,并将复张容积与动脉氧合进行相关性分析。
研究组纳入11例符合ARDS标准的机械通气患者。采用压力-容积曲线法测量三种不同PEEP水平[5 cm H2O、10 cm H2O、15 cm H2O(1 cm H2O = 0.098 kPa)]时的复张容积。比较不同PEEP水平对肺力学和气体交换的影响。
当PEEP从5 cm H2O增加到15 cm H2O时,肺复张容积升高[(40.2±15.3)ml对(123.8±43.1)ml对(178.9±43.5)ml,P均<0.05]。动脉氧合指数随PEEP增加,复张容积与动脉氧合指数变化呈正相关(r = 0.483,P<0.01)。在固定潮气量下,不同PEEP水平时的静态顺应性无显著差异(P>0.05)。低拐点(LIP)患者组在PEEP为15 cm H2O时的复张容积大于无LIP组。
复张容积随PEEP增加,PEEP引起的动脉氧合增加与复张容积显著相关。