Smith Dean W, Henry Mark H
Department of Orthopaedics, University of Texas School of Medicine, Houston, TX, USA.
J Hand Surg Am. 2004 Jul;29(4):703-6. doi: 10.1016/j.jhsa.2004.04.006.
Distinctive to volar fixed-angle plating of the distal radius, the optimal position of the distal fixed-angle support is in the subchondral bone immediately proximal to the articular surface. Standard intraoperative radiographic imaging of the distal radius during placement of a volar fixed-angle plate does not provide adequate visualization of the subchondral bone-distal support interface. A 45 degrees pronated oblique view is described to address this specific issue of whether volar hardware placed at the immediate subchondral bone level has effectively avoided the radiocarpal joint. This is a quite important radiographic consideration when pursuing the strategy of volar fixed-angle plating of distal radius fractures.