Balan Corneliu, Balut Corina, Gheorghe Liana, Gheorghe Cristian, Gheorghiu Eugen, Ursu George
"Politehnica" University of Bucharest, Department of Bioengineering and Biotechnology, REOROM Group, Romania.
Clin Hemorheol Microcirc. 2004;30(3-4):359-64.
The paper is concerned with the determination of blood permittivity and conductivity in Poiseuille and Couette simple shear flows. The experimental procedure, based on dielectric spectroscopy, evidences the sensitivity of blood electric properties to the applied frequency and local shear rate magnitude. The method evidences the possibility to correlate (for well-defined flow geometry) magnitude of shear rate, and consequently the shear stress level, with spectra permittivity of blood.