Wade S E
Hammersmith Laboratories, Inc., Springs, CO 80477.
Clin Chem. 1992 Sep;38(9):1878-82.
Performance of a new oral-diffusion-sink (ODS) device for sampling the steroid hormones cortisol, progesterone, estradiol, and testosterone from human saliva was tested in vitro. The tested device differed from an earlier ODS sampler by using a polymeric composition of beta-cyclodextrin rather than an antiserum to bind analytes diffusing into the device. The capacity of the cyclodextrin-driven device to accumulate the steroid hormones from a simple buffer, human saliva, and saliva fortified with high concentrations of glucocorticosteroids was evaluated. Further, the ability of this device to accurately register the average analyte concentration resulting from treatments simulating physiological episodic secretion events was tested. Each steroid showed a characteristic rate of uptake that was unaffected by saliva or high physiological concentrations of competing steroids, and ODS uptake resulting from temporally varied concentrations of the hormone in the medium accurately reflected the time-integrated average concentration. This ODS provides a potential noninvasive and unobtrusive means of sampling the tissue-available concentrations of multiple steroid hormones, with averaging over physiological secretion events.
对一种新型口腔扩散吸收(ODS)装置进行了体外测试,该装置用于从人唾液中采集类固醇激素皮质醇、孕酮、雌二醇和睾酮。测试的装置与早期的ODS采样器不同,它使用β-环糊精的聚合物组合物而非抗血清来结合扩散到装置中的分析物。评估了环糊精驱动装置从简单缓冲液、人唾液以及添加高浓度糖皮质激素的唾液中积累类固醇激素的能力。此外,还测试了该装置准确记录模拟生理性间歇性分泌事件处理后平均分析物浓度的能力。每种类固醇都显示出特征性的摄取速率,不受唾液或高生理浓度竞争性类固醇的影响,并且培养基中激素浓度随时间变化导致的ODS摄取准确反映了时间积分平均浓度。这种ODS提供了一种潜在的非侵入性且不引人注意的方法,用于采集多种类固醇激素的组织可用浓度,并对生理性分泌事件进行平均。