Suppr超能文献

放血和硝普钠对主动脉阻断期间椎管顺应性的影响。

Effects of exsanguination and sodium nitroprusside on compliance of the spinal canal during aortic occlusion.

作者信息

Maughan R E, Mohan C, Levy R, Cunningham J N, Jacobowitz I, Marini C P

机构信息

Department of Surgery, SUNY Health Science Center, Brooklyn, New York.

出版信息

J Surg Res. 1992 Jun;52(6):571-6. doi: 10.1016/0022-4804(92)90131-i.

Abstract

To evaluate the effects of sodium nitroprusside (SNP) and partial exsanguination (EXS) on systemic hemodynamics and cerebrospinal fluid dynamics, we monitored proximal and distal blood pressure (BP), cerebrospinal fluid pressure (CSFP), spinal cord perfusion pressure (SCPP), and compliance of the spinal canal (CSC) in 10 mongrel dogs during aortic cross-clamping of the descending thoracic aorta. CSC was measured by serial injections of 2 ml of saline solution into the cisterna cerebellomedullaris via a percutaneously placed catheter with simultaneous measurements of CSFP. Data were acquired at baseline (BL), during aortic cross-clamping with proximal hypertension (AXC), and after control of proximal hypertension with EXS and SNP. During the cross-clamp interval, mean proximal aortic pressure (PxBP) rose from 114 +/- 6 to 150 +/- 3 mm Hg (P less than 0.001), whereas mean blood pressure decreased to 88 +/- 5 and 82 +/- 4 mm Hg during the SNP and EXS intervals, respectively (P less than 0.05 vs BL). EXS and SNP were equally effective in controlling PxBP (82 +/- 4 vs 88 +/- 5 mm Hg, P greater than 0.05). Mean distal aortic pressure (DsBP) decreased from systemic values to 21.5 +/- 1.9 mm Hg during AXC, and to 12.4 +/- 1.0 and to 8 +/- 0.8 mm Hg during EXS and SNP, respectively (P less than 0.05 AXC vs EXS and SNP). SNP lowered DsBP significantly more than EXS, 8 +/- 0.8 vs 12.4 +/- 1.0 mm Hg (P less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

为评估硝普钠(SNP)和部分放血(EXS)对全身血流动力学和脑脊液动力学的影响,我们在10只杂种犬胸降主动脉交叉钳夹期间,监测了近端和远端血压(BP)、脑脊液压力(CSFP)、脊髓灌注压(SCPP)以及椎管顺应性(CSC)。通过经皮放置的导管向小脑延髓池连续注射2 ml盐溶液并同时测量CSFP来测定CSC。在基线(BL)、近端高血压的主动脉交叉钳夹期间(AXC)以及用EXS和SNP控制近端高血压后采集数据。在交叉钳夹期间,平均近端主动脉压(PxBP)从114±6 mmHg升至150±3 mmHg(P<0.001),而在SNP和EXS期间平均血压分别降至88±5 mmHg和82±4 mmHg(与BL相比,P<0.05)。EXS和SNP在控制PxBP方面同样有效(82±4 mmHg对88±5 mmHg,P>0.05)。平均远端主动脉压(DsBP)在AXC期间从全身值降至21.5±1.9 mmHg,在EXS和SNP期间分别降至12.4±1.0 mmHg和8±0.8 mmHg(AXC与EXS和SNP相比,P<0.05)。SNP降低DsBP的幅度明显大于EXS,分别为8±0.8 mmHg和12.4±1.0 mmHg(P<0.05)。(摘要截断于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验