Suppr超能文献

通过对带有不透射线标记物的每日门静脉成像进行三维分析,测量前列腺在分次内的运动以及分次间和分次内的旋转。

Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers.

作者信息

Aubry Jean-François, Beaulieu Luc, Girouard Louis-Martin, Aubin Sylviane, Tremblay Daniel, Laverdière Jacques, Vigneault Eric

机构信息

Département de Radio-Oncologie and Centre de Recherche en Cancérologie de l'Université Laval, Hôtel-Dieu de Québec, Centre Hospitalier Universitaire de Québec, 11 Cote du Palais, PQ G1R 2J6, Québec, Canada.

出版信息

Int J Radiat Oncol Biol Phys. 2004 Sep 1;60(1):30-9. doi: 10.1016/j.ijrobp.2004.02.045.

Abstract

PURPOSE

To measure the interfraction and intrafraction motion of the prostate during the course of external beam radiotherapy using a video electronic portal imaging device and three-dimensional analysis.

METHODS AND MATERIALS

Eighteen patients underwent implantation with two or three gold markers in the prostate before five-angle/11-field conformal radiotherapy. Using CT data as the positional reference, multiple daily sets of portal images, and a three-dimensional reconstruction algorithm, intrafraction translations, as well as interfraction and intrafraction rotations, were analyzed along the three principal axes (left-right [LR], superoinferior [SI], and AP). The overall mean values and standard deviations (SDs), along with random and systematic SDs, were computed for these translations and rotations.

RESULTS

For 282 intrafraction translational displacements, the random SD was 0.8 mm (systematic SD, 0.2) in the LR, 1.0 mm (systematic SD, 0.4) in the SI, and 1.4 mm (systematic SD, 0.7) in the AP axes. The analysis of 348 interfraction rotations revealed random SDs of 6.1 degrees (systematic SD, 5.6 degrees ) around the LR axis, 2.8 degrees (systematic SD, 2.4 degrees ) around the SI axis, and 2.0 degrees (systematic SD, 2.2 degrees ) around the AP axis. The intrafraction rotational motion observed during 44 fractions had a random SD of 1.8 degrees (systematic SD, 1.0 degrees ) around the LR, 1.1 degrees (systematic SD, 0.8 degrees ) around the SI, and 0.6 degrees (systematic SD, 0.3 degrees ) around the AP axis.

CONCLUSION

The interfraction rotations observed were more important than those reported in previous studies. Intrafraction motion was generally smaller in magnitude than interfraction motion. However, the intrafraction rotations and translations of the prostate should be taken into account when designing planning target volume margins because their magnitudes are not negligible.

摘要

目的

使用视频电子射野影像装置和三维分析方法,测量体外照射放疗过程中前列腺的分次间和分次内运动。

方法和材料

18例患者在进行五角度/11野适形放疗前,于前列腺内植入两到三个金标记物。以CT数据作为位置参考,利用每日多组射野影像以及三维重建算法,沿三个主轴(左右[LR]、上下[SI]和前后[AP])分析分次内平移以及分次间和分次内旋转。计算这些平移和旋转的总体平均值、标准差(SD)以及随机和系统标准差。

结果

对于282次分次内平移位移,LR轴上随机标准差为0.8毫米(系统标准差为0.2),SI轴上为1.0毫米(系统标准差为0.4),AP轴上为1.4毫米(系统标准差为0.7)。对348次分次间旋转的分析显示,围绕LR轴的随机标准差为6.1度(系统标准差为5.6度),围绕SI轴为2.8度(系统标准差为2.4度),围绕AP轴为2.0度(系统标准差为2.2度)。在44次分次过程中观察到的分次内旋转运动,围绕LR轴的随机标准差为1.8度(系统标准差为1.0度),围绕SI轴为1.1度(系统标准差为0.8度),围绕AP轴为0.6度(系统标准差为0.3度)。

结论

观察到的分次间旋转比先前研究报道的更为重要。分次内运动的幅度通常比分次间运动小。然而,在设计计划靶区边界时应考虑前列腺的分次内旋转和平移,因为它们的幅度不可忽略。