Suppr超能文献

Angle dependence of response characteristics of neutron survey instruments.

作者信息

Roberts N J, Bartlett D T, Hager L G, Jones L N, Molinos C, Tanner R J, Taylor G C, Thomas D J

机构信息

National Physical Laboratory, Teddington, Middlesex TW11 0LW, UK.

出版信息

Radiat Prot Dosimetry. 2004;110(1-4):187-93. doi: 10.1093/rpd/nch130.

Abstract

Neutron area survey instruments are designed to have an approximately isotropic response. In practice, the response cannot be perfectly isotropic for instruments that do not have spherical symmetry, and for all instruments it is modified by the inclusion of batteries, electronics, handles, etc. This affects the ability of the survey instrument to measure accurately an isotropic dose equivalent quantity. Measurements of the angle dependence of response for four of the most commonly used designs of survey instrument (Harwell 0949, Mark 7 NRM, NM2 and Studsvik 2202D) have been performed in a low-scatter room using radionuclide and monoenergetic neutron sources. The Monte Carlo code MCNP has been used to model the responses and to investigate their sensitivity to the polyethylene density, counting gas pressure and other manufacturing tolerances. Preliminary modelling results are presented here.

摘要

相似文献

1
Angle dependence of response characteristics of neutron survey instruments.
Radiat Prot Dosimetry. 2004;110(1-4):187-93. doi: 10.1093/rpd/nch130.
2
Practical implications of neutron survey instrument performance.
Radiat Prot Dosimetry. 2004;110(1-4):763-7. doi: 10.1093/rpd/nch207.
3
Present status of the personal neutron dosemeter based on direct ion storage.
Radiat Prot Dosimetry. 2004;110(1-4):213-7. doi: 10.1093/rpd/nch127.
4
Measurement of energy and direction distribution of neutron and photon fluences in workplace fields.
Radiat Prot Dosimetry. 2004;110(1-4):237-41. doi: 10.1093/rpd/nch179.
5
Performance of a cylindrical tissue-equivalent proportional counter for use in neutron monitoring.
Radiat Prot Dosimetry. 2004;110(1-4):297-300. doi: 10.1093/rpd/nch169.
7
A new area multidetector dosemeter for mixed n-gamma fields.
Radiat Prot Dosimetry. 2004;110(1-4):243-8. doi: 10.1093/rpd/nch123.
8
AMANDE: a new facility for monoenergetic neutron fields production between 2 keV and 20 MeV.
Radiat Prot Dosimetry. 2004;110(1-4):49-52. doi: 10.1093/rpd/nch185.
9
The electronic neutron/photon dosemeter PTB DOS-2002.
Radiat Prot Dosimetry. 2004;110(1-4):291-5. doi: 10.1093/rpd/nch180.
10
Development of active environmental and personal neutron dosemeters.
Radiat Prot Dosimetry. 2004;110(1-4):169-81. doi: 10.1093/rpd/nch158.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验