Suppr超能文献

Self-shielding effects in neutron spectra measurements for neutron capture therapy by means of activation foils.

作者信息

Pytel Krzysztof, Józefowicz Krystyna, Pytel Beatrycze, Koziel Alina

机构信息

Institute of Atomic Energy, 05-400 Otwock-Swierk, Poland.

出版信息

Radiat Prot Dosimetry. 2004;110(1-4):823-6. doi: 10.1093/rpd/nch134.

Abstract

The design and optimisation of a neutron beam for neutron capture therapy (NCT) is accompanied by the neutron spectra measurements at the target position. The method of activation detectors was applied for the neutron spectra measurements. Epithermal neutron energy region imposes the resonance structure of activation cross sections resulting in strong self-shielding effects. The neutron self-shielding correction factor was calculated using a simple analytical model of a single absorption event. Such a procedure has been applied to individual cross sections from pointwise ENDF/B-VI library and new corrected activation cross sections were introduced to a spectra unfolding algorithm. The method has been verified experimentally both for isotropic and for parallel neutron beams. Two sets of diluted and non-diluted activation foils covered with cadmium were irradiated in the neutron field. The comparison of activation rates of diluted and non-diluted foils has demonstrated the correctness of the applied self-shielding model.