• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Continuous monitoring of mixed venous oxygen saturation during aortic operations.

作者信息

Powelson J A, Maini B S, Bishop R L, Sottile F D

机构信息

Department of Surgery, Fallon Clinic, Worcester, MA 01606.

出版信息

Crit Care Med. 1992 Mar;20(3):332-6. doi: 10.1097/00003246-199203000-00007.

DOI:10.1097/00003246-199203000-00007
PMID:1541093
Abstract

OBJECTIVE

To systematically analyze the changes in mixed venous oxygen saturation (delta SvO2) during aortic operations with tube, aortobi-iliac, and aortobifemoral grafts.

DESIGN

Survey of consecutive patients.

SETTING

Teaching community hospital.

PATIENTS

Thirty-one patients (22 male, 9 female, mean age 67 +/- 10 yrs), undergoing elective operations for aortic aneurysms (n = 25) and aortoiliac occlusive disease (n = 6).

INTERVENTIONS

SvO2 was recorded throughout the operation. Cardiac output, mean pulmonary arterial pressure, arterial oxygen saturation (SaO2), and arterial pH were measured before and immediately after the unclamping of the aortic graft.

RESULTS

In all patients, unclamping the aorta resulted in a marked reduction of mean SvO2, with no change in the cardiac output or SaO2. The unclamping of tube grafts was associated with a significant reduction in arterial pH (p less than .01) and in SvO2 (p less than .001), when compared with unclamping of bifurcation grafts. A significant (p less than .05) increase in mean pulmonary arterial pressure was observed after unclamping the aorta in patients with tube grafts. Despite a longer clamp time, unclamping the second limb of a bifurcation graft resulted in a smaller delta SvO2, when compared with that observed after unclamping the first limb (12% vs. 6%; p less than .01). The delta SvO2 after unclamping limb II was only 2% in aortobifemoral grafts and 9% in aortobi-iliac grafts.

CONCLUSIONS

Reperfusion via extensive pelvic and lumbar collaterals in patients with aortoiliac occlusive disease reduces the delta SvO2 after aortic unclamping. Monitoring the changes in SvO2 during different types of aortic reconstruction helps to define precisely the physiologic alterations that occur in the course of these operations.

摘要

相似文献

1
Continuous monitoring of mixed venous oxygen saturation during aortic operations.
Crit Care Med. 1992 Mar;20(3):332-6. doi: 10.1097/00003246-199203000-00007.
2
Continuous monitoring of mixed venous oxygen saturation during aortic surgery.
Chest. 1987 Nov;92(5):796-9. doi: 10.1378/chest.92.5.796.
3
[Factors determining late patency of aortobifemoral bypass graft].[决定主-双股动脉旁路移植术远期通畅率的因素]
Srp Arh Celok Lek. 1997 Jan-Feb;125(1-2):24-35.
4
Continuous monitoring of mixed venous oxygen saturation during orthotopic liver transplantation.
J Cardiothorac Vasc Anesth. 1992 Jun;6(3):283-6. doi: 10.1016/1053-0770(92)90140-3.
5
Oxygen uptake and mixed venous oxygen saturation during aortic surgery and the first three postoperative hours.
Anesth Analg. 1991 Nov;73(5):530-5. doi: 10.1213/00000539-199111000-00003.
6
Clinical implications of intraoperative continuous mixed venous oxygen saturation monitoring.术中持续混合静脉血氧饱和度监测的临床意义
AANA J. 1989 Feb;57(1):45-52.
7
Continuous monitoring of mixed venous oxygen saturation during aortofemoral bypass grafting.在主动脉股动脉旁路移植术中对混合静脉血氧饱和度进行连续监测。
Am Surg. 1986 Feb;52(2):114-5.
8
Calculated versus measured oxygen consumption during aortic surgery: reliability of the Fick method.主动脉手术期间计算的与测量的氧耗:菲克法的可靠性
Anesth Analg. 1994 Feb;78(2):253-6. doi: 10.1213/00000539-199402000-00010.
9
Evaluation of right ventricular function during aortic operations.
Arch Surg. 1993 May;128(5):582-4; discussion 585. doi: 10.1001/archsurg.1993.01420170118018.
10
Mixed venous oxygen saturation in abdominal aortic surgery: intraoperative hypothermia and vasodilator therapy implications.腹主动脉手术中混合静脉血氧饱和度:术中低温及血管扩张剂治疗的影响
Int Surg. 1990 Oct-Dec;75(4):234-7.

引用本文的文献

1
Noninvasive cerebral oximeter as a surrogate for mixed venous saturation in children.无创脑血氧仪作为儿童混合静脉血氧饱和度的替代指标
Pediatr Cardiol. 2007 Jan-Feb;28(1):34-41. doi: 10.1007/s00246-006-1379-z. Epub 2007 Jan 9.