High-throughput chiral analysis of albuterol enantiomers in dog plasma using on-line sample extraction/polar organic mode chiral liquid chromatography with tandem mass spectrometric detection.

作者信息

Wu Steven T, Xing Jinsong, Apedo Atsu, Wang-Iverson David B, Olah Timothy V, Tymiak Adrienne A, Zhao Ning

机构信息

Pharmaceutical Candidate Optimization, Bristol-Myers Squibb Pharmaceutical Research Institute, P.O. Box 4000, Princeton, NJ 08543, USA.

出版信息

Rapid Commun Mass Spectrom. 2004;18(21):2531-6. doi: 10.1002/rcm.1655.

Abstract

An automated chiral chromatography/tandem mass spectrometry bioanalytical method for the determination of albuterol in dog plasma was developed. The method employed on-line sample extraction using turbulent flow chromatography coupled to a Chirobiotic T column for chiral separation using a polar organic mobile phase consisting of methanol, 0.02% formic acid, and 0.1% ammonium formate. The analytes were detected by a tandem mass spectrometer operated in positive ion mode. The (S)- and (R)-isomers were resolved chromatographically with retention times of 5.1 and 5.6 min, respectively. The analytical run time was 8 min. The enantiomers did not interconvert either in mobile phase or in dog plasma at room temperature over the course of at least 2 h. The assay has a linear dynamic range from 2.5-2500 nM for both enantiomers. The lower limit of quantitation (LLOQ) was 2.5 nM for both enantiomers using 50 microL of plasma. The accuracy and precision of intraday validation were determined at five concentration levels of six replicates. The accuracy of the method for the (R)-isomer ranged from 94-103% of nominal concentrations, and the precision (%CV) ranged from 3.6-12%. The accuracy of the method for the (S)-isomer ranged from 94.5-108% of nominal concentrations, and the precision ranged from 3.2-9.3%. Interday accuracy and precision were evaluated for three days at five concentrations for one replicate. The accuracy of the method for the (R)-isomer ranged from 98-110% of nominal concentrations, and the precision ranged from 1.5-10.6%. The accuracy of the method for the (S)-isomer ranged from 96-104% of nominal concentrations, and the precision ranged from 1.5-8.7%. The combination of turbulent flow on-line sample extraction with polar organic mode chiral chromatography provided a specific, rugged, and high-throughput method for the chiral analysis of albuterol in biological fluids.

摘要

建立了一种用于测定犬血浆中沙丁胺醇的自动化手性色谱/串联质谱生物分析方法。该方法采用在线样品萃取,使用湍流色谱与Chirobiotic T柱联用,以由甲醇、0.02%甲酸和0.1%甲酸铵组成的极性有机流动相进行手性分离。通过在正离子模式下运行的串联质谱仪检测分析物。(S)-和(R)-异构体通过色谱分离,保留时间分别为5.1和5.6分钟。分析运行时间为8分钟。在室温下至少2小时内,对映体在流动相或犬血浆中均未发生相互转化。该测定法对两种对映体的线性动态范围均为2.5 - 2500 nM。使用50微升血浆时,两种对映体的定量下限(LLOQ)均为2.5 nM。日内验证的准确性和精密度在五个浓度水平下进行了六次重复测定。该方法对(R)-异构体的准确性在标称浓度的94% - 103%之间,精密度(%CV)在3.6% - 12%之间。该方法对(S)-异构体的准确性在标称浓度的94.5% - 108%之间,精密度在3.2% - 9.3%之间。日间准确性和精密度在五个浓度下进行了三天的单次重复评估。该方法对(R)-异构体的准确性在标称浓度的98% - 110%之间,精密度在1.5% - 10.6%之间。该方法对(S)-异构体的准确性在标称浓度的96% - 104%之间,精密度在1.5% - 8.7%之间。湍流在线样品萃取与极性有机模式手性色谱相结合,为生物流体中沙丁胺醇的手性分析提供了一种特异、耐用且高通量的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验