Jepsen Søren, Ayna Mustafa, Hedderich Jürgen, Eberhard Jörg
Department of Periodontology, Operative and Preventive Dentistry, University of Bonn, Germany.
J Clin Periodontol. 2004 Nov;31(11):1003-6. doi: 10.1111/j.1600-051X.2004.00601.x.
Ultrasonic scalers have become increasingly popular for subgingival debridement. The aim of the present study was to investigate the influence of different working tip designs (narrow versus wide) on root substance loss caused by either magnetostrictive or piezoelectric ultrasonic devices.
In this in vitro study, a magnetostrictive ultrasonic system with either Slimline or TFI-10 inserts and a piezoelectric ultrasonic system with either Perioprobe or Type-A inserts were compared at different application forces. Loss of root dentin was determined by defect width, defect depth and defect volume resulting from standardized instrumentation using laser profilometry.
There were consistent and statistically significant differences between all groups. The mean observed dentin alterations for the magnetostrictive ultrasonic device operating a Slimline insert at a lateral force of 0.3 N were 254.4 microm, 6.3 microm and 22.5 microm3 and for the TFI-10 tip 759.0 microm, 23.5 microm and 160.2 microm3 for the parameters defect width, depth and volume, respectively. For the piezoelectric ultrasonic system operating a Perioprobe insert, the corresponding mean values were 352.0 microm/12.1 microm/56.4 microm3 and for the universal Type-A insert they were 402.4 microm/14.0 microm/133.4 microm3. With application forces of 0.7 N, root substance removal increased up to twofold.
The present investigation could demonstrate that the aggressiveness of magnetostrictive and piezoelectric ultrasonic devices to root substance was significantly influenced by the scaler tip designs, increasing for wider scaler tips as compared with narrow, probe-shaped inserts.
超声洁牙机在龈下刮治中越来越受欢迎。本研究的目的是调查不同工作头设计(窄头与宽头)对磁致伸缩或压电超声设备导致的牙根物质损失的影响。
在这项体外研究中,比较了配备Slimline或TFI - 10工作头的磁致伸缩超声系统以及配备Perioprobe或A型工作头的压电超声系统在不同施加力下的情况。使用激光轮廓仪通过标准化器械操作产生的缺损宽度、缺损深度和缺损体积来确定牙根牙本质的损失。
所有组之间存在一致且具有统计学意义的差异。对于在0.3 N侧向力下操作Slimline工作头的磁致伸缩超声设备,观察到的牙本质平均改变在缺损宽度、深度和体积参数方面分别为254.4微米、6.3微米和22.5立方微米;对于TFI - 10工作头,相应的值分别为759.0微米、23.5微米和160.2立方微米。对于操作Perioprobe工作头的压电超声系统,相应的平均值分别为352.0微米/12.1微米/56.4立方微米;对于通用A型工作头,它们分别为402.4微米/14.0微米/133.4立方微米。在施加力为0.7 N时,牙根物质去除量增加至两倍。
本研究表明,磁致伸缩和压电超声设备对牙根物质的侵蚀性受洁牙机头设计的显著影响,与窄的、探针形状的工作头相比,宽的洁牙机头导致的牙根物质损失更多。