Brinker Mark R, Gugenheim Joseph J, O'Connor Daniel P, London Jeffrey C
Center for Problem Fractures and Limb Restoration, Fondren Orthopedic Group, Texas Orthopedic Hospital, Houston, Texas 77030, USA.
Am J Orthop (Belle Mead NJ). 2004 Oct;33(10):489-93.
Ideally, acquired femoral malrotation as a complication of intramedullary nailing of a femoral shaft fracture should be identified and corrected early in the course of treatment. In this report, we present a previously undescribed precise surgical technique for acutely correcting an acquired femoral malrotation deformity 20 days after fixation of a femoral shaft fracture with a statically locked intramedullary nail. An llizarov external fixator was used intraoperatively to correct a 27 degree femoral malrotation deformity in a 19-year-old man.