Berkhout W E R, Mileman P A, Weerheijm K L
Uit de de afdeling Tandheelkundige Radiologie, Academisch Centrum Tandheelkunde Amsterdam (ACTA).
Ned Tijdschr Tandheelkd. 2004 Oct;111(10):382-7.
In dentistry, digital radiology techniques, such as a charge-coupled device and a storage phosphor plate, are gaining popularity. It was the objective of this study to assess the importance of the advantages and disadvantages of digital radiology techniques for bitewing radiography in young children, when compared to conventional film. A group of dentists received a questionnaire regarding their experiences with digital radiology techniques or conventional films among young children. Using the Simple Multi-Attributive Rating Technique (SMART) a final weighted score was calculated for the charge-coupled device, the phosphor plate, and conventional film. The scores were 7.40, 7.38, and 6.98 respectively. The differences were not statistically significant (p > 0.47). It could be concluded that, on the basis of experiences in practice, there are no statistically significant preferences for the use of digital radioogy techniques for bitewing radiography in young children.