Suppr超能文献

What is the best way to assess microsatellite instability status in colorectal cancer? Study on a population base of 462 colorectal cancers.

作者信息

Chapusot C, Martin L, Puig P Laurent, Ponnelle T, Cheynel N, Bouvier A M, Rageot D, Roignot P, Rat P, Faivre J, Piard F

机构信息

Service d'Anatomie Pathologique, Dijon, Faculté de Médecine, Dijon, France.

出版信息

Am J Surg Pathol. 2004 Dec;28(12):1553-9. doi: 10.1097/00000478-200412000-00002.

Abstract

The assessment of the microsatellite instability (MSI) status in colorectal cancers is presently warranted for three reasons: 1) as a screening tool for hereditary nonpolyposis colorectal cancer, 2) as a prognostic marker, and 3) as a potential predictive factor of chemotherapy response. The aim of this study was to evaluate, on a large scale with tissue samples coming from a number of different sources, the difficulties met with routine use of immunohistochemistry (IHC) and to determine if it really does offer an accurate alternative to PCR genotyping. Colorectal carcinomas from 462 consecutive patients resected in public or private hospitals were assessed for MSI status by two methods: MSI testing (with BAT-26 microsatellite) and IHC detection of hMLH1, hMSH2, and hMSH6 proteins. Of the 398 cancers tested, immunohistochemistry was noncontributory in 42 (10.5%), focal in 9 (2.3%), and discordant with the PCR results in 36 (9%). For these 87 cases, complementary analyses were performed to explain discrepancy. After additional IHC assay with modified processing protocols, 8 cases remained noncontributory, 2 focal, and 28 discordant: 18 microsatellite stability IHC/MSI PCR and 10 MSI IHC/microsatellite stability PCR. For these discordant cases, we performed a multiplex PCR assay on DNA extracted from the frozen sample and BAT-26 was amplified from DNA extracted from the paraffin blocks used for IHC. Four discordant cases were reclassified after PCR multiplex assay (3 as MSI and 1 as microsatellite stability). Five other cases displayed intratumoral heterogeneity and 19 remained discordant. The discrepancy could be partly explained by variable technical protocols of fixation in the different laboratories, leading to variations in staining quality and difficulties in IHC interpretation. This population-based study is the first one to show that IHC is not sensitive and specific enough to be used routinely. Immunohistochemistry analysis of MMR proteins must be performed in standardized conditions and interpreted by confirmed pathologists. It cannot replace PCR as long as protocols are not optimized and harmonized.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验