Odenthal M T P, Gan I M, Oosting J, Kijlstra A, Beekhuis W H
Department of Ophthalmology, Academic Medical Center, 1100 DE Amsterdam, The Netherlands.
Cornea. 2005 Jan;24(1):32-8. doi: 10.1097/01.ico.0000138860.97302.5a.
Low gas-permeable contact lens wear of polymethyl methacrylate or hydroxyethyl methacrylate material is known to cause morphologic abnormalities in the corneal endothelial cell layer. These lenses were widely prescribed and successfully worn until their use was actively discouraged in the late 1980s and early 1990s. This study was designed to investigate whether discontinuation of low gas-permeable contact lens wear leads to an improvement of corneal endothelial cell morphology.
At the time of discontinuation and at least 5 years after discontinuation of low gas-permeable contact lens wear, noncontact specular photographs of the central corneal endothelium were made in 66 patients (14 male and 52 female, mean age 37.7 +/- 8.4, range 24.6-69.0). By computer analysis of endothelial photographs, parameters for polymegethism and pleomorphism were calculated, as well as cell density.
Mean follow-up time between photographs was 6.8 years (SD 1.1). Sixty-one patients were refitted with rigid high gas-permeable contact lenses or high-water-content soft lenses, and 5 patients switched to spectacle wear. A small but significant recovery of the corneal endothelial cell morphology was found for the mean coefficient of variation of cell area, from 37.5 to 35.7 (P = 0.022), and for the coefficient of variation of the number of sides, from 13.1 to 12.4 (P = 0.004). The mean percentage of hexagonal cells increased from 54.2 to 56.2 (P = 0.013). Although the corneal endothelial cell morphology improved significantly on cessation of LGP contact lens wear, the values did not return to levels observed in normal, non-contact lens wearing individuals. During follow-up, the mean endothelial cell density decreased significantly (P = 0.001) from 2994 to 2890 (a 3.5% cell loss in 6.8 years), which is similar to the known normal age-related cell loss of 0.6% per year in non-contact lens wearing healthy individuals.
Endothelial polymegethism and pleomorphism caused by PMMA or HEMA contact lens wear is partly reversible.
已知聚甲基丙烯酸甲酯或甲基丙烯酸羟乙酯材料的低透气性隐形眼镜佩戴会导致角膜内皮细胞层出现形态异常。这些隐形眼镜曾被广泛处方并成功佩戴,直到20世纪80年代末和90年代初其使用被积极劝阻。本研究旨在调查停止佩戴低透气性隐形眼镜是否会导致角膜内皮细胞形态改善。
在停止佩戴低透气性隐形眼镜时以及停止佩戴至少5年后,对66例患者(14例男性和52例女性,平均年龄37.7±8.4岁,范围24.6 - 69.0岁)的中央角膜内皮进行非接触式镜面照相。通过对内皮照片进行计算机分析,计算多形性和异形性参数以及细胞密度。
两次照相之间的平均随访时间为6.8年(标准差1.1)。六十一例患者重新佩戴了硬性高透气性隐形眼镜或高含水量软性隐形眼镜,5例患者改为佩戴框架眼镜。发现角膜内皮细胞形态有小但显著的恢复,细胞面积的平均变异系数从37.5降至35.7(P = 0.022),边数变异系数从13.1降至12.4(P = 0.004)。六边形细胞的平均百分比从54.2增加到56.2(P = 0.013)。尽管停止佩戴低透气性隐形眼镜后角膜内皮细胞形态显著改善,但这些值并未恢复到正常未佩戴隐形眼镜个体所观察到的水平。在随访期间,平均内皮细胞密度从2994显著下降(P = 0.001)至2890(6.8年内细胞损失3.5%),这与未佩戴隐形眼镜的健康个体每年已知的正常年龄相关细胞损失0.6%相似。
由PMMA或HEMA隐形眼镜佩戴引起的内皮多形性和异形性部分是可逆的。