Data compression for storage of resting ECGs digitized at 500 samples/second.

作者信息

Reddy B R, Christenson D W, Rowlandson G I, Zywietz C, Sheffield T, Brohet C

机构信息

Diagnostics Division, Marquette Electronics, Inc., Milwaukee, Wisconsin 53223.

出版信息

Biomed Instrum Technol. 1992 Mar-Apr;26(2):133-49.

PMID:1562827
Abstract

Data compression of resting electrocardiograms (ECGs) digitized at 500 samples per second (sps) is presented. Tradeoffs between the fidelity of reconstructed data and the overall compression are examined. Data of the median (average) complexes are retained at 500 sps and full resolution and encoded only to reduce redundancy. The raw data for rhythm analysis are evaluated for lowpass filtering and down-sampling (decimation) and requantization. After subtracting the medians from the raw data, the resulting residue signal is examined in detail for data reduction and encoding. Various options for compression of the residue signal are presented. Specific issues examined are the acceptable decimation and requantization of the residue signal. Another important aspect evaluated is the bimodal decimation of the QRS and the rest of the cardiac complex. Here, the QRS complexes are kept at 500 sps and the rest of the data decimated to lower sampling rates. This novel approach reduces data distortion while achieving significant compression. Details of the compression scheme and its evaluation on uncompressed 500-sps ECGs from the European Common Standards for Electrocardiography (CSE) database (128 ECGs with normal sinus rhythm, atrioventricular blocks, atrial fibrillation and flutter, ventricular arrhythmias, and excessive noise) are elucidated. Performance indexes [root mean square (RMS) error, percent RMS difference, normalized RMS difference, maximum peak error, and compression ratio] are computed. To validate the compression method, qualitative evaluation was performed by two physicians overreading the ECGs by comparing the reconstructed waveforms with the original uncompressed data. The median data are retained at 500 sps and full precision. For rhythm data, the bimodal decimation of the residue signal to 125 sps at 10 microvolts resolution preserved the fidelity of the ECG signals well, while giving good data compression. Abnormal atrial activity was well preserved and the QRS was retained without distortion. The average size of a 10-sec compressed ECG with the medians is around 4.5 kilobytes.

摘要

相似文献

1
Data compression for storage of resting ECGs digitized at 500 samples/second.
Biomed Instrum Technol. 1992 Mar-Apr;26(2):133-49.
2
Analysis of interval measurements on CSE multilead reference ECGs.对CSE多导联参考心电图的间期测量分析。
J Electrocardiol. 1996;29 Suppl:62-6. doi: 10.1016/s0022-0736(96)80021-5.
3
Prospective evaluation of a microprocessor-assisted cardiac rhythm algorithm: results from one clinical center.微处理器辅助心律算法的前瞻性评估:来自一个临床中心的结果。
J Electrocardiol. 1998;30 Suppl:28-33. doi: 10.1016/s0022-0736(98)80016-2.
4
ECG compression and recognition using complete tree representation.使用完全树表示法的心电图压缩与识别
Biomed Sci Instrum. 1997;34:113-8.
5
Data compression of electrocardiograms for long-time digital recording in IC memory.用于在集成电路存储器中进行长时间数字记录的心电图数据压缩
Front Med Biol Eng. 1992;4(4):291-9.
6
Atrial fibrillation detection on compressed sensed ECG.基于压缩感知心电图的心房颤动检测
Physiol Meas. 2017 Jun 27;38(7):1405-1425. doi: 10.1088/1361-6579/aa7652.
7
Digitization of Electrocardiogram From Telemetry Prior to In-hospital Cardiac Arrest: A Pilot Study.住院心脏骤停前遥测心电图的数字化:一项初步研究。
Biol Res Nurs. 2016 Mar;18(2):230-6. doi: 10.1177/1099800415602092. Epub 2015 Aug 27.
8
Is a higher sampling rate desirable in the computer processing of the pediatric electrocardiogram?
J Electrocardiol. 1987 Nov;20(5):321-8. doi: 10.1016/s0022-0736(87)80083-3.
9
An ECG signal compressor based on the selection of optimal threshold levels of discrete wavelet transform coefficients.一种基于离散小波变换系数最优阈值水平选择的心电图信号压缩器。
J Med Eng Technol. 2008 Nov-Dec;32(6):425-33. doi: 10.1080/03091900701455763.
10
ECGScan: a method for conversion of paper electrocardiographic printouts to digital electrocardiographic files.心电图扫描:一种将纸质心电图打印件转换为数字心电图文件的方法。
J Electrocardiol. 2005 Oct;38(4):310-8. doi: 10.1016/j.jelectrocard.2005.04.003.