Pertussis diagnosis among adults is primarily based on serology. In this study, receiver operation characteristics (ROC) analysis was utilized to evaluate three IgA, IgM and IgG ELISAs based on B. pertussis whole-cell sonicate (WC), pertussis toxin (PT), or combined PT-filamentous haemagglutinin (FHA) antigens in a healthy adult population and in adults suffering from symptoms consistent with pertussis. The assays were compared to a PT and FHA reference ELISA. The reference assay showed high correlation with PT- and PT-FHA-based ELISAs but low correlation was found with the WC-based ELISA. However, ROC analysis indicated that all the assays enabled fine differentiation between healthy subjects and subjects suffering from symptoms suggestive of pertussis. The WC IgA ELISA showed the best diagnostic performance [highest specificity (98.8%) with highest sensitivity (53.8%)]. We conclude that despite a low correlation between the various assays they all carry good diagnostic capability for an adult population.
成人百日咳的诊断主要基于血清学。在本研究中,利用受试者操作特征(ROC)分析,在健康成人人群以及出现与百日咳相符症状的成人中,评估了基于百日咳博德特氏菌全细胞超声裂解物(WC)、百日咳毒素(PT)或PT-丝状血凝素(FHA)组合抗原的三种IgA、IgM和IgG酶联免疫吸附测定(ELISA)。将这些检测方法与PT和FHA参考ELISA进行比较。参考检测方法与基于PT和PT-FHA的ELISA显示出高度相关性,但与基于WC的ELISA相关性较低。然而,ROC分析表明,所有检测方法都能够很好地区分健康受试者和出现百日咳症状的受试者。WC IgA ELISA显示出最佳的诊断性能[最高特异性(98.8%)和最高敏感性(53.8%)]。我们得出结论,尽管各种检测方法之间的相关性较低,但它们对成人人群都具有良好的诊断能力。