A comparative study of a modified catheter-mediated direct current and radiofrequency ablation on atrioventricular junction.

作者信息

Chen S A, Hsia C P, Tsang W P, Wang T C, Ting C T, Wang S P, Chiang B N, Kong C W, Chang M S

机构信息

Department of Medicine, National Yang-Ming Medical College, Taipei, Republic of China.

出版信息

Jpn Heart J. 1992 Jan;33(1):49-59. doi: 10.1536/ihj.33.49.

DOI:10.1536/ihj.33.49
PMID:1573779
Abstract

Conventional His-bundle ablation, performed at the site with the largest His-bundle potential, displays a high incidence of a new right bundle branch block with loss of pacemaker escape. Damage to the perinodal atrial area may decrease the injury to the His-bundle, such that the escape pacemaker activity with a narrow QRS complex is produced. This study reports data from 25 patients with drug-refractory atrial tachyarrhythmias. Nine patients (group I) received radiofrequency (RF) ablation of the atrioventricular junction (AVJ). General anesthesia was not necessary in group I patients. During a mean follow-up period of 10 months, a complete AV block persisted in 5 patients, and a first degree AV block persisted in 2 patients; these patients were asymptomatic and did not require treatment with antiarrhythmic agents. A successful direct-current (DC) ablation was performed in one of the patients with an unsuccessful RF lesion, producing a new right bundle branch block (RBBB). Sixteen patients (group II) received DC ablation of the AVJ. During a mean follow-up period of 20 months, a complete AV block persisted in 9 patients, a first degree AV block was produced in 7 patients, and a new RBBB occurred in 2 patients. Fifteen patients (94%) were asymptomatic without administration of antiarrhythmic agents. Complications, including nonsustained ventricular tachycardia (1 patient) and pericarditis (1 patient), occurred immediately after ablation in group II. Myocardial injury, reflected by creatine kinase-MB isoenzyme, was higher in group II than in group I (25 +/- 2 vs 10 +/- 1 IU/l). We conclude that (1) catheter-mediated RF ablation of the AV junction is safer than DC ablation, (2) a majority of patients with drug-refractory atrial tachyarrhythmias can be successfully treated with RF ablation and (3) failure to achieve AV junction ablation with RF does not mitigate against successful application of DC ablation.

摘要

相似文献

1
A comparative study of a modified catheter-mediated direct current and radiofrequency ablation on atrioventricular junction.
Jpn Heart J. 1992 Jan;33(1):49-59. doi: 10.1536/ihj.33.49.
2
Catheter ablation of the atrioventricular junction with radiofrequency energy.经导管射频能量房室交界区消融术
Circulation. 1989 Dec;80(6):1527-35. doi: 10.1161/01.cir.80.6.1527.
3
Radiofrequency catheter ablation of the atrioventricular junction from the left ventricle.经左心室行房室结射频导管消融术
Circulation. 1991 Aug;84(2):567-71. doi: 10.1161/01.cir.84.2.567.
4
A prospective randomized comparison of direct current and radiofrequency ablation of the atrioventricular junction.房室结直流电消融与射频消融的前瞻性随机对照研究
J Am Coll Cardiol. 1993 Jan;21(1):102-9. doi: 10.1016/0735-1097(93)90723-e.
5
High success rate of atrioventricular node ablation with radiofrequency energy.射频能量房室结消融成功率高。
J Am Coll Cardiol. 1991 Dec;18(7):1753-8. doi: 10.1016/0735-1097(91)90516-c.
6
Catheter ablation of atrioventricular junction using radiofrequency current in 17 patients. Comparison of standard and large-tip catheter electrodes.17例患者使用射频电流对房室结进行导管消融。标准导管电极与大尖端导管电极的比较。
Circulation. 1991 May;83(5):1562-76. doi: 10.1161/01.cir.83.5.1562.
7
[Transcatheter radiofrequency modulation and ablation of the atrioventricular junction in supraventricular arrhythmias refractory to medical therapy].
Cardiologia. 1992 Apr;37(4):275-83.
8
Catheter ablation of the atrioventricular junction using radiofrequency energy and a bilateral cardiac approach.
Am J Cardiol. 1992 Dec 1;70(18):1438-43. doi: 10.1016/0002-9149(92)90296-b.
9
Catheter ablation for recurrent tachyarrhythmias. Clinical experience with two different techniques of ablation in 21 patients.复发性快速心律失常的导管消融术。21例患者两种不同消融技术的临床经验。
Pacing Clin Electrophysiol. 1988 Nov;11(11 Pt 2):1945-53. doi: 10.1111/j.1540-8159.1988.tb06333.x.
10
Follow-up of a modified catheter ablation of the atrioventricular junction in patients with atrial tachyarrhythmias.
Zhonghua Yi Xue Za Zhi (Taipei). 1992 Nov;50(5):370-4.