The purpose of this study was to investigate the relationship between air-plethysmographic volume parameters under standard exercise loading and foot venous pressure parameters under ideal exercise loading in patients with primary varicose veins.
Seventy-one lower limbs in 39 patients with primary varicose veins and 8 lower limbs in 4 healthy controls were examined. The patients included 12 males and 27 females, ranging in age from 36 to 79 years. Eighteen limbs were asymptomatic (class 0) limbs, 28 limbs had symptoms of swelling or heaviness (class 1), and 25 had skin lesions (class 2+3). The patients and controls were examined with duplex scanning, air-plethysmography, and ambulatory foot venous pressure measurement.
The mean ambulatory venous pressure (AVP) was significantly higher in the class 2+3 limbs than in the other classes, but it was not significantly higher in class 1 than in class 0. There were no significant differences between the class 2+3 limbs and class 1 limbs in any of the air-plethysmographic parameters. However, the VFI in the class 0 limbs was significantly different from that in the other 2 groups. Among all parameters examined, the venous filling index (VFI) was the most closely correlated with the AVP. All air-plethysmographic parameters were negatively correlated with the VRT.
Among non-invasive air-plethysmographic volume parameters, VFI is the most reliable indicator for quantitative evaluation of calf pump function.
本研究旨在探讨原发性静脉曲张患者在标准运动负荷下的空气体积描记法容积参数与理想运动负荷下的足部静脉压力参数之间的关系。
对39例原发性静脉曲张患者的71条下肢和4例健康对照者的8条下肢进行了检查。患者包括12名男性和27名女性,年龄在36至79岁之间。18条下肢无症状(0级),28条下肢有肿胀或沉重症状(1级),25条有皮肤病变(2 + 3级)。对患者和对照者进行了双功扫描、空气体积描记法和动态足部静脉压力测量。
2 + 3级下肢的平均动态静脉压力(AVP)显著高于其他级别,但1级下肢的AVP与0级相比无显著升高。2 + 3级下肢与1级下肢在任何空气体积描记参数上均无显著差异。然而,0级下肢的静脉充盈指数(VFI)与其他两组显著不同。在所有检查参数中,静脉充盈指数(VFI)与AVP的相关性最强。所有空气体积描记参数与静脉回流时间(VRT)均呈负相关。
在无创空气体积描记法容积参数中,VFI是定量评估小腿泵功能最可靠的指标。