Karakurt Lokman, Ozdemir Huseyin, Yilmaz Erhan, Inci Murat, Belhan Oktay, Serin Erhan
Department of Orthopaedics and Traumatology bDepartment of Radiology, Firat University, Faculty of Medicine, Elazig, Turkey.
J Pediatr Orthop B. 2005 May;14(3):189-93. doi: 10.1097/01202412-200505000-00009.
After the 12.6-month (3-30) follow-up period, the morphology and dynamics of the ulnar nerve in the cubital tunnel were examined with ultrasonography on operated (group 1) and opposite (group 2) elbows of 13 children who had percutaneous cross-pin fixation for displaced supracondylar humerus fractures. When we compared group 1 and group 2, nerve morphology was similar (P>0.05), but nerve dynamics were found to be decreased or absent for seven (54%) elbows in group 1 (P<0.05). The medial K-wire may damage the ulnar nerve dynamics in the cubital tunnel.
在12.6个月(3 - 30个月)的随访期后,对13例因肱骨髁上骨折移位而接受经皮交叉克氏针固定的儿童,在其手术侧(第1组)和对侧(第2组)肘部使用超声检查尺神经在肘管内的形态和动态情况。当我们比较第1组和第2组时,神经形态相似(P>0.05),但发现第1组中有7例(54%)肘部的神经动态降低或消失(P<0.05)。内侧克氏针可能会损害肘管内尺神经的动态。