Zeppieri M, Brusini P, Miglior S
Department of Ophthalmology, Santa Maria della Misericordia Hospital, Udine, Italy.
Eur J Ophthalmol. 2005 Mar-Apr;15(2):196-201. doi: 10.1177/112067210501500203.
To correlate functional damage over time detected by standard automated perimetry (SAP) and frequency doubling technology (FDT) with central corneal thickness (CCT) in patients with ocular hypertension (OHT).
Seventy-eight OHT patients underwent CCT measurements, SAP, and FDT (the latter two also after 12 and 18 months). Patients were divided into three equally sized groups of 26 patients each: thin (< 540 microm), normal (540-580 microm), and thick cornea (> 580 microm). The frequency of abnormal FDT and SAP results was analyzed over time (Pearson chi2 test).
Six of 26 patients with thin corneas (23.1%) presented an abnormal FDT test at baseline, compared to 1 of 26 (3.8%) in the normal thickness cornea group and 1 of 26 (3.8%) in the thick cornea group. After 12 months, the abnormal FDT tests were as follows, respectively: 9 of 26 (34.6%), 2 of 26 (7.7%), and 2 of 26 (7.7%). For SAP the abnormal results were as follows, respectively: 8 (30.1%), 5 (19.2%), and 2 (7.7%). After 18 months, the abnormal FDT tests were as follows, respectively: 16 (61.5%), 5 (19.2%), and 5 (19.2%). For SAP, the abnormal results were as follows, respectively: 10 (38.5%), 5 (19.2%), and 2 (7.7%).
OHT patients with thinner corneas have a greater risk of developing functional damage over time.
探讨眼压升高(OHT)患者标准自动视野计(SAP)和倍频视野计(FDT)随时间检测到的功能损害与中央角膜厚度(CCT)之间的相关性。
78例OHT患者接受了CCT测量、SAP和FDT检查(后两项检查在12个月和18个月后也进行了)。患者被分为三组,每组26例,分别为薄角膜组(<540微米)、正常角膜组(540 - 580微米)和厚角膜组(>580微米)。分析随时间异常FDT和SAP结果的发生率(Pearson卡方检验)。
26例薄角膜患者中有6例(23.1%)在基线时FDT检查异常,正常厚度角膜组为26例中的1例(3.8%),厚角膜组为26例中的1例(3.8%)。12个月后,FDT检查异常率分别为:26例中的9例(34.6%)、26例中的2例(7.7%)和26例中的2例(7.7%)。SAP检查异常结果分别为:8例(30.1%)、5例(19.2%)和2例(7.7%)。18个月后,FDT检查异常率分别为:16例(61.5%)、5例(19.2%)和5例(19.2%)。对于SAP,异常结果分别为:10例(38.5%)、5例(19.2%)和2例(7.7%)。
角膜较薄的OHT患者随着时间推移发生功能损害的风险更高。