Suppr超能文献

使用三重四极杆和四极杆离子阱质谱分析仪的液相色谱法测定橙子中农药残留的比较。

Comparison of liquid chromatography using triple quadrupole and quadrupole ion trap mass analyzers to determine pesticide residues in oranges.

作者信息

Soler Carla, Mañes Jordi, Picó Yolanda

机构信息

Laboratori de Bromatologia i Toxicologia, Facultat de Farmàcia, Universitat de València, 46100 Burjassot, València, Spain.

出版信息

J Chromatogr A. 2005 Mar 4;1067(1-2):115-25. doi: 10.1016/j.chroma.2004.10.032.

Abstract

Liquid chromatography-triple quadrupole/mass spectrometry (LC-TQ/MS) and liquid chromatography-quadrupole ion trap/mass spectrometry (LC-QIT/MS) for determining bupirimate, hexaflumuron, tebufenpyrad, buprofezin, pyriproxyfen, and fluvalinate in fruits have been compared. The differences in the mass spectra obtained by triple and ion trap quadrupoles are discussed, showing how both of them provide interesting features. The evaluation of the two instruments was carried out by ethyl acetate extraction of oranges spiked with the studied pesticides at LOQ and 10 times the LOQ. Results obtained by LC-TQ/MS correlated well with those obtained by LC-QIT/MS. Recoveries were 70-94% by LC-TQ/MS and 72-92% by LC-QIT/MS with the R.S.D. from five replicate analysis 4-14% and 8-18%, respectively. Matrix effects were tested for both techniques by standard addition to blank extracts. Although the matrix effects are not originated in mass analyzer but in the LC/MS interface, they were, generally, more marked by LC-QIT-MS than by LC-TQ/MS. The limits of quantification (LOQs) were 0.005-0.2 mg kg(-1) by both equipments--appropriate values for determining these pesticides in orange from the regulatory point of view. The results indicate that the TQ provides higher precision, better linearity, it is more robust, and when the purpose of the analysis is quantitative determination, preferable over the QIT. However, the application of both mass spectrometers to analyze orange samples conventionally treated showed that any can be used for qualitative and quantitative purposes.

摘要

已对用于测定水果中必螨立克、氟铃脲、吡螨胺、噻嗪酮、吡丙醚和氟胺氰菊酯的液相色谱 - 三重四极杆/质谱联用仪(LC - TQ/MS)和液相色谱 - 四极杆离子阱/质谱联用仪(LC - QIT/MS)进行了比较。讨论了三重四极杆和离子阱四极杆获得的质谱差异,展示了它们如何都具有有趣的特性。通过用乙酸乙酯萃取添加了定量限(LOQ)和10倍定量限的所研究农药的橙子来对这两种仪器进行评估。LC - TQ/MS获得的结果与LC - QIT/MS获得的结果相关性良好。LC - TQ/MS的回收率为70 - 94%,LC - QIT/MS的回收率为72 - 92%,五次重复分析的相对标准偏差(R.S.D.)分别为4 - 14%和8 - 18%。通过向空白提取物中添加标准品对两种技术的基质效应进行了测试。尽管基质效应并非源于质量分析器而是源于LC/MS接口,但一般来说,LC - QIT - MS的基质效应比LC - TQ/MS更明显。两种设备的定量限(LOQ)均为0.005 - 0.2 mg kg⁻¹ —— 从监管角度来看,这些值适合用于测定橙子中的这些农药。结果表明,三重四极杆(TQ)具有更高的精密度、更好的线性,更稳健,并且当分析目的是定量测定时,比离子阱(QIT)更可取。然而,将这两种质谱仪应用于分析常规处理的橙子样品表明,任何一种都可用于定性和定量目的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验