Dierckx R, Dobbeleir A, Vandevivere J, Abts H, DeDeyn P P
Department of Nuclear Medicine, Middelheim General Hospital, Antwerp, Belgium.
Clin Nucl Med. 1992 May;17(5):378-9. doi: 10.1097/00003072-199205000-00008.
The authors explored the high spatial resolution of a three-head rotating SPECT system, equipped with lead super-fine fanbeam collimator. The brainstem was high-lighted in a three-dimensional reconstruction, showing perfusion small structures such as mesencephalon, pons, and medulla oblongata. The visualization of brainstem perfusion sets new landmarks in functional neuroimaging and, moreover, was obtained with a commercially available three-head SPECT system.
作者们探索了配备铅超细扇形束准直器的三头旋转单光子发射计算机断层扫描(SPECT)系统的高空间分辨率。在三维重建中脑干被凸显出来,显示出中脑、脑桥和延髓等灌注小结构。脑干灌注的可视化在功能神经成像方面树立了新的标志,而且是通过商用三头SPECT系统实现的。