Suppr超能文献

利用压电生物传感器灵敏检测河水中的有机磷酸盐。

Sensitive detection of organophosphates in river water by means of a piezoelectric biosensor.

作者信息

Halámek J, Pribyl Jan, Makower A, Skládal P, Scheller F W

机构信息

Analytical Biochemistry, University Potsdam, Karl-Liebknecht Str. 24-25, 14476 Golm, Germany.

出版信息

Anal Bioanal Chem. 2005 Aug;382(8):1904-11. doi: 10.1007/s00216-005-3260-y. Epub 2005 May 20.

Abstract

A highly sensitive piezoelectric biosensor has been developed for detection of cholinesterase inhibitors. The inhibitor benzoylecgonine-1,8-diamino-3,4-dioxaoctane (BZE-DADOO) was immobilized on a monolayer of 11-mercaptomonoundecanoic acid (MUA) self-assembled on the gold surface of the sensor. The binding of high-molecular-weight cholinesterase to the immobilized cocaine derivative was monitored with a mass sensitive piezoelectric quartz crystal (quartz crystal nanobalance; QCN). In the presence of an inhibiting substance in the sample, the binding of cholinesterase to the immobilized inhibitor was reduced. The decrease of the rate of mass change was proportional to the concentration of free inhibitor in the sample. This way the affinity sensor followed anti-cholinesterase toxicity and the enzyme activity of ChE was not addressed. A assay for detection of organophosphates (OP) was optimized. Regeneration of the sensor surface was achieved with 1 mol L(-1) formic acid, which enabled 40 measurements with one sensor. All assays were carried out in a flow-through arrangement. The total measurement time (binding+regeneration) was 25 min and the detection limit for different OP (paraoxon, diisopropylfluorophosphate, chlorpyriphos, and chlorfenvinphos) was down to 10(-10) mol L(-1) (0.02 microg L(-1)). This sensor was used for determination of organophosphate (diisopropylfluorophosphate) levels in river water samples.

摘要

已开发出一种用于检测胆碱酯酶抑制剂的高灵敏度压电生物传感器。抑制剂苯甲酰芽子碱 - 1,8 - 二氨基 - 3,4 - 二氧杂辛烷(BZE - DADOO)固定在自组装于传感器金表面的11 - 巯基十一烷酸(MUA)单分子层上。用质量敏感型压电石英晶体(石英晶体纳米天平;QCN)监测高分子量胆碱酯酶与固定化可卡因衍生物的结合情况。在样品中存在抑制物质时,胆碱酯酶与固定化抑制剂的结合减少。质量变化速率的降低与样品中游离抑制剂的浓度成正比。通过这种方式,亲和传感器可追踪抗胆碱酯酶毒性,而未涉及胆碱酯酶的酶活性。优化了一种用于检测有机磷(OP)的分析方法。用1 mol L⁻¹甲酸实现传感器表面的再生,这使得一个传感器能够进行40次测量。所有分析均采用流通式装置进行。总测量时间(结合 + 再生)为25分钟,不同有机磷(对氧磷、二异丙基氟磷酸酯、毒死蜱和毒虫畏)的检测限低至10⁻¹⁰ mol L⁻¹(0.02 μg L⁻¹)。该传感器用于测定河水样品中的有机磷(二异丙基氟磷酸酯)含量。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验