Suppr超能文献

使用敏感性编码的肝脏改良磁共振血管造影与数字减影血管造影和CT动脉门静脉造影的比较

Modified magnetic resonance angiography of the liver using sensitivity encoding in comparison with digital subtraction angiography and CT arterial portography.

作者信息

Yan Sen-Xiang, Liang Ting-Bo, Fujii Masahiko, Kawamitsu Hideaki, Sugimura Kazuro, Zheng Shu-Sen

机构信息

Department of Radiology, First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China.

出版信息

Hepatobiliary Pancreat Dis Int. 2005 May;4(2):185-91.

Abstract

BACKGROUND

Over 355 patients have received orthotopic liver transplantation (OLT) at this hospital since 1993. Preoperative imaging studies of both hepatic vessels and parenchyma in these recipients bettered surgical planning or even precluded the necessity of surgery. Here we report our preliminary results of modified magnetic resonance angiography (MRA) using sensitivity encoding (SENSE) through comparative study with conventional digital subtraction angiography (DSA) and CT arterial portography (CTAP).

METHODS

Sixteen patients with suspected liver diseases were included in the study. All of them received both dynamic MRI of the liver using SENSE and digital DSA with CTAP within a two-week interval. The four-phase MRA was reconstructed from source images of the coronal dynamic study. The arterial phase of the modified MRA was compared with DSA in the evaluation of hepatic arteries and the portal phase compared with CT portography reconstructed from source images of CTAP. In dynamic study of the liver, a fixed dose (20 ml) of contrast medium and scan timing were used.

RESULTS

The main branches and variations of the hepatic arterial system were well shown on the modified MRA, although the marginal branches of hepatic arteries were of poor quality. The figures of portal veins on MRA were as clear as or superior to those of CTAP. In addition, the suprarenal inferior vena cava (IVC) was well demonstrated on MRA and/or non contrast-enhanced coronal balanced fast-field echo (b-FFE) scan sequence in most cases. MRI detected most parenchymal lesions of the liver and hemodynamics of these lesions could be evaluated on source images of the modified MRA. MRI/MRA also serendipitously revealed several extrahepatic disease entities or variations that were not found on DSA/CTAP.

CONCLUSIONS

The modified MRA using SENSE is a cost-effective modality of examination for the demonstration of the whole hepatic vascular system. Combined with MRI, it has the potential as a one-stop imaging modality in the preoperative evaluation in fields such as OLT.

摘要

背景

自1993年以来,超过355例患者在本院接受了原位肝移植(OLT)。对这些受者的肝血管和实质进行术前影像学检查,改善了手术规划,甚至排除了手术的必要性。在此,我们通过与传统数字减影血管造影(DSA)和CT动脉门静脉造影(CTAP)的对比研究,报告使用敏感性编码(SENSE)的改良磁共振血管造影(MRA)的初步结果。

方法

16例疑似肝脏疾病的患者纳入本研究。他们均在两周内接受了使用SENSE的肝脏动态MRI检查以及数字DSA和CTAP检查。从冠状面动态研究的源图像重建四期MRA。在评估肝动脉时,将改良MRA的动脉期与DSA进行比较,门静脉期与从CTAP源图像重建的CT门静脉造影进行比较。在肝脏动态研究中,使用固定剂量(20 ml)的造影剂和扫描时间。

结果

改良MRA能很好地显示肝动脉系统的主要分支和变异,尽管肝动脉的边缘分支质量较差。MRA上门静脉的图像与CTAP的图像一样清晰或更清晰。此外,在大多数情况下,改良MRA和/或非增强冠状面平衡快速场回波(b-FFE)扫描序列能很好地显示肾上腺下腔静脉(IVC)。MRI检测到肝脏的大多数实质病变,并且可以在改良MRA的源图像上评估这些病变的血流动力学。MRI/MRA还意外地发现了一些DSA/CTAP未发现的肝外疾病实体或变异。

结论

使用SENSE的改良MRA是一种经济有效的检查方式,可用于显示整个肝血管系统。与MRI相结合,它有潜力成为OLT等领域术前评估中的一站式成像方式。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验