Suppr超能文献

16层螺旋CT回顾性重建技术测量冠状动脉钙化的重复性变异

Variability of repeated coronary artery calcium measurements by 16-MDCT with retrospective reconstruction.

作者信息

Horiguchi Jun, Yamamoto Hideya, Akiyama Yuji, Hirai Nobuhiko, Marukawa Kazushi, Fukuda Hiroshi, Ito Katsuhide

机构信息

Department of Clinical Radiology, Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551, Japan.

出版信息

AJR Am J Roentgenol. 2005 Jun;184(6):1917-23. doi: 10.2214/ajr.184.6.01841917.

Abstract

OBJECTIVE

High reproducibility on coronary calcium scoring is an important factor in monitoring the progression of coronary atherosclerosis. The purposes of this study were, using a 16-MDCT scanner with retrospective reconstruction, to compare the effects of thin-slice images and overlapping image reconstruction on the reproducibility of coronary calcium scoring and to compare 16-MDCT with electron beam CT (EBCT).

MATERIALS AND METHODS

Fifty patients underwent two sequential examinations using both EBCT and MDCT. For MDCT, images were reconstructed from the same raw data using the following thicknesses and increments (thickness/increment): 1.25 mm/1.25 mm, 2.5 mm/2.5 mm, and 2.5 mm/1.25 mm. The Agatston, volume, and mass scores were calculated on four pairs of image sets. Statistical analysis was performed to determine significant differences in interscan variability among image acquisition protocols and among measurement algorithms.

RESULTS

Overlapping reconstructed images (thickness/increment, 2.5 mm/1.25 mm) obtained on a 16-MDCT scanner showed the lowest variability (mean, 13%; median, 10%) when compared with the Agatston score.

CONCLUSION

The use of 16-MDCT with overlapping reconstruction by retrospective reconstruction, yielding low variability of coronary artery calcium measurement on two sequential scans, has an advantage over EBCT in monitoring the progression of atherosclerosis.

摘要

目的

冠状动脉钙化积分的高重复性是监测冠状动脉粥样硬化进展的重要因素。本研究的目的是,使用具有回顾性重建功能的16层螺旋CT扫描仪,比较薄层图像和重叠图像重建对冠状动脉钙化积分重复性的影响,并将16层螺旋CT与电子束CT(EBCT)进行比较。

材料与方法

50例患者先后接受了EBCT和MDCT检查。对于MDCT,使用以下层厚和层间距(层厚/层间距)从相同的原始数据重建图像:1.25mm/1.25mm、2.5mm/2.5mm和2.5mm/1.25mm。在四组图像上计算阿加斯顿积分、容积积分和质量积分。进行统计分析以确定图像采集方案和测量算法之间扫描间变异性的显著差异。

结果

与阿加斯顿积分相比,16层螺旋CT扫描仪获得的重叠重建图像(层厚/层间距,2.5mm/1.25mm)显示出最低的变异性(均值,13%;中位数,10%)。

结论

使用具有回顾性重建功能的16层螺旋CT进行重叠重建,在两次连续扫描中冠状动脉钙化测量的变异性较低,在监测动脉粥样硬化进展方面比EBCT具有优势。