Luska G, Nüsslin F, Wagner H H
Rofo. 1979 Oct;131(4):349-55. doi: 10.1055/s-0029-1231450.
Duplicate examinations were carried out on 122 patients in order to compare the results of mammography using a grid technique (Diagnost U. Müller) with a film-screen systemadn also a conventional set without screens (Mamma-Diagnost, Müller). The results were compared with reference to film quality and dose. The new technique was superior to the conventional method in all respects, independent of the size of the gland. Another advantage of the grid technique was the larger available film size. Dose requirements for grid mammography with a film-screen system was less than for conventional techniques by a factor of about 1.8. The results speak for increased use of the grid technique in clinical practice.
为了比较使用格栅技术(Diagnost U. Müller)的乳腺X线摄影结果与胶片-增感屏系统以及无增感屏的传统设备(Mamma-Diagnost,Müller)的结果,对122例患者进行了重复检查。根据胶片质量和剂量对结果进行了比较。新技术在所有方面均优于传统方法,与腺体大小无关。格栅技术的另一个优点是可用胶片尺寸更大。使用胶片-增感屏系统的格栅乳腺X线摄影的剂量要求比传统技术低约1.8倍。结果表明应在临床实践中更多地使用格栅技术。