• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Correlation and agreement analysis between standard videotape and digital echocardiography: a cross-sectional study.

作者信息

Hatem Maria Amélia Bulhões, Castro Iran, Hatem Domingos, Zuccolotto Marços, Schuck Adalberto, Pellanda Lúcia, Pandolfo Fernanda, Feier Flávia

机构信息

Programa de Pós-Gradução, Instituto de Cardiologia do Rio Grande do Sul, Fundação Universitária de Cardiologia, Brasil.

出版信息

Rev Port Cardiol. 2005 Mar;24(3):331-45.

PMID:15929619
Abstract

BACKGROUND

Several studies have analyzed the correlation between digital and standard videotape echocardiographic images. The advantages of digital echocardiography are a faster exam, lower costs and a greater number of exams performed. Our study's aim was to evaluate the correlation and agreement between cardiac dimensions measured by M-mode and two-dimensional echocardiography, using the Echo Off Line free software, and by standard echocardiography.

METHODS

This was a cross-sectional, randomized study, in 56 patients, whose images were acquired during echocardiographic examination. Left ventricular systolic and diastolic diameters, septal and posterior wall thicknesses, and left atrial and aortic diameters were measured using the Echo Off Line program. These measures were compared to those acquired using the standard method by a different sonographer, through correlation and agreement analysis as described by Bland and Altman. Values of p<0.05 were considered significant.

RESULTS

The correlation index between the methods varied from 0.85 to 0.98 (Pearson's correlation coefficient) for all the variables studied. The analysis showed that there was good agreement between the methods for most of the measures, the mean difference being close to zero. The variability in absolute values, for most measures, did not reach clinical significance. The method's reproducibility (intra-observer) was adequate. This measurement tool demonstrated correlation indices similar to those in the literature consulted, as well as adequate reproducibility indices for intra-observer measures. Its low cost, compared to that of imported workstations on the market, means it can be widely used without significant costs (free software).

CONCLUSION

There is a direct correlation and good agreement between M-mode and two-dimensional echocardiographic measures of cardiac dimensions obtained by the Echo Off Line program and by the standard videotape-based method. The Echo Off Line program can be used routinely in echocardiography laboratories.

摘要

相似文献

1
Correlation and agreement analysis between standard videotape and digital echocardiography: a cross-sectional study.
Rev Port Cardiol. 2005 Mar;24(3):331-45.
2
[Correlation and concordance between echocardiographic measurements obtained during echocardiography and digitized image measurements--transversal study].[超声心动图检查期间获得的超声心动图测量值与数字化图像测量值之间的相关性和一致性——横向研究]
Arq Bras Cardiol. 2006 Apr;86(4):283-8. doi: 10.1590/s0066-782x2006000400008. Epub 2006 Apr 25.
3
[Three dimensional reconstruction in intracoronary echography: a new system with automatic contour definition of ecg-gated image acquisition].冠状动脉内超声的三维重建:一种具有心电图门控图像采集自动轮廓定义的新系统
Cardiologia. 1997 Nov;42(11):1159-64.
4
Analysis of cardiac dimensions, mass and function in heart transplant recipients using 64-slice multi-detector computed tomography.使用64层多探测器计算机断层扫描分析心脏移植受者的心脏尺寸、质量和功能。
J Heart Lung Transplant. 2007 May;26(5):478-84. doi: 10.1016/j.healun.2007.01.041. Epub 2007 Mar 26.
5
[Assessment of aortic stenosis after aortic valve replacement: comparative evaluation of dual-source CT and echocardiography].主动脉瓣置换术后主动脉瓣狭窄的评估:双源CT与超声心动图的对比评价
Rofo. 2008 Jun;180(6):553-60. doi: 10.1055/s-2008-1027288.
6
Comparison of contrast agent-enhanced versus non-contrast agent-enhanced real-time three-dimensional echocardiography for analysis of left ventricular systolic function.对比剂增强与非对比剂增强实时三维超声心动图分析左心室收缩功能的比较
Am J Cardiol. 2007 Nov 1;100(9):1485-9. doi: 10.1016/j.amjcard.2007.06.042. Epub 2007 Aug 24.
7
Association between left atrial myocardial function and exercise capacity in patients with either idiopathic or ischemic dilated cardiomyopathy: a two-dimensional speckle strain study.特发性或缺血性扩张型心肌病患者左心房心肌功能与运动能力之间的关联:一项二维斑点追踪应变研究
Int J Cardiol. 2009 Mar 6;132(3):354-63. doi: 10.1016/j.ijcard.2007.11.102. Epub 2008 Feb 5.
8
Measurement of left ventricular mass by real-time three-dimensional echocardiography: validation against magnetic resonance and comparison with two-dimensional and m-mode measurements.实时三维超声心动图测量左心室质量:与磁共振成像的对比验证及与二维和M型测量的比较
J Am Soc Echocardiogr. 2008 Sep;21(9):1001-5. doi: 10.1016/j.echo.2008.07.008.
9
Sample volume positioning in colour-coded Doppler myocardial imaging: effect of systolic and diastolic tracking.彩色编码多普勒心肌成像中的样本容积定位:收缩期和舒张期追踪的影响
Ultrasound Med Biol. 2009 Feb;35(2):186-92. doi: 10.1016/j.ultrasmedbio.2008.08.020. Epub 2008 Nov 17.
10
Inter- and intra-observer variability in Sonographic measurements of the cross-sectional diameters and area of the umbilical cord and its vessels during pregnancy.孕期超声测量脐带及其血管的横截面积和直径时观察者间及观察者内的变异性。
Reprod Health. 2008 Oct 15;5:5. doi: 10.1186/1742-4755-5-5.