Koch David E, Bhandari Alok, Closb Larry, Hunter Robert P
Zoological and Analytical Pharmacology Laboratory, Department of Anatomy and Physiology, College of Veterinary Medicine, Kansas State University, Manhattan, KS, USA.
J Chromatogr A. 2005 May 13;1074(1-2):17-22. doi: 10.1016/j.chroma.2005.03.052.
Azithromycin is a broad spectrum antimicrobial agent that is approved in the United States for use in humans. Due to azithromycin's low rate of metabolism it is likely to be found in wastewater treatment plants, where its broad spectrum of antimicrobial activity could lead to development of resistance in bacteria. A liquid-liquid extraction using K2CO3 and methyl-t-butyl ether (MTBE) was used to extract azithromycin from 10 ml aliquots of wastewater. Liquid chromatography was performed using a Luna C18(2) (30 mm x 2.0 mm) column with a mass spectrometer friendly mobile phase containing 50:24:2:24 acetonitrile, methanol, tetrahydrofuran, and 0.04 M ammonium hydroxide. The mass spectrometer used an electrospray source with positive ionization and an ion trap detector. A linear standard curve from 5 to 200pg/ml was validated and used to quantitate azithromycin in wastewater.
阿奇霉素是一种在美国被批准用于人类的广谱抗菌剂。由于阿奇霉素的代谢率较低,它很可能会在污水处理厂中被发现,在那里其广谱抗菌活性可能会导致细菌产生耐药性。使用碳酸钾和甲基叔丁基醚(MTBE)进行液液萃取,从10毫升废水等分试样中提取阿奇霉素。使用Luna C18(2)(30mm×2.0mm)色谱柱进行液相色谱分析,流动相为对质谱仪友好的,包含50:24:2:24的乙腈、甲醇、四氢呋喃和0.04M氢氧化铵。质谱仪使用带有正离子化的电喷雾源和离子阱检测器。验证了5至200pg/ml的线性标准曲线,并用于定量废水中的阿奇霉素。