To compare performance of visual inspection and Laser fluorescence methods to detect occlusal caries lesions under clinical and laboratory conditions in permanent teeth.
One hundred and ten sites in 57 third molars scheduled for extraction were examined with visual inspection and laser fluorescence (DIAGNOdent) device by two trained examiners. After the extraction, teeth were re-examined. Then, teeth were sectioned to perform histological validation. Best cut-off points were calculated with ROC analysis, and sensitivity, specificity and accuracy were calculated at D2 and D3 thresholds. Comparisons between the methods and conditions of examination were performed using McNemar test. Inter-examiner agreement in the same conditions and agreement between the methods performed in vivo and in vitro conditions were assessed by Kappa test. Laser fluorescence values obtained in two conditions were compared with Wilcoxon test.
No difference was observed with visual inspection in both conditions. Laser fluorescence performed in vitro presented higher specificity and accuracy at D3 threshold. Visual inspection showed higher reproducibility. After adjustment of cut-off points for laser fluorescence method, there was no difference between the evaluated parameters.
Only slightly differences were observed between the examinations performed under clinical and laboratory conditions in the detection of occlusal caries lesions in permanent teeth.
比较视觉检查和激光荧光法在临床和实验室条件下检测恒牙咬合面龋损的性能。
由两名经过培训的检查者使用视觉检查和激光荧光(DIAGNOdent)设备对57颗计划拔除的第三磨牙的110个部位进行检查。拔牙后,对牙齿进行重新检查。然后,将牙齿切片进行组织学验证。通过ROC分析计算最佳截断点,并在D2和D3阈值下计算敏感性、特异性和准确性。使用McNemar检验对检查方法和检查条件之间进行比较。通过Kappa检验评估相同条件下检查者之间的一致性以及体内和体外条件下方法之间的一致性。使用Wilcoxon检验比较在两种条件下获得的激光荧光值。
在两种条件下,视觉检查均未观察到差异。体外进行的激光荧光在D3阈值下具有更高的特异性和准确性。视觉检查显示出更高的可重复性。在调整激光荧光法的截断点后,评估参数之间没有差异。
在临床和实验室条件下检测恒牙咬合面龋损时,观察到的差异很小。