Suppr超能文献

未麻醉去大脑猫耳蜗背核神经元放电的时间特性分析

Analysis of temporal discharge characteristics of dorsal cochlear nucleus neurons of unanesthetized decerebrate cats.

作者信息

Parham K, Kim D O

机构信息

Department of Surgery, University of Connecticut Health Center, Farmington 06030.

出版信息

J Neurophysiol. 1992 May;67(5):1247-63. doi: 10.1152/jn.1992.67.5.1247.

Abstract
  1. We examined the mean and standard deviation (SD) of interspike intervals (ISI) and the coefficient of variation (CV, the ratio of SD of ISI to mean ISI) of ISIs versus time to study discharge regularity of units in the dorsal cochlear nucleus (DCN) of decerebrate unanesthetized cats. The units were characterized by the use of both poststimulus time histograms (PSTH) and excitatory-inhibitory area (EI-area) schemes. We present results of a systematic examination of all of 87 DCN pause-build units recorded in this study. In addition, we present examples of chopper subtypes of the DCN. 2. A major finding of this study is that a majority of the pause-build units in the present sample exhibited regular discharges in response to short (50 ms) tone bursts at characteristic frequency (CF), as revealed by CVs less than 0.5. A predominant portion of pause-build units (80% of 44 units with sufficient number of spikes for CV analysis) exhibited mean CVs less than 0.5 in the 20- to 39.9-ms time window in response to 50-ms tone burst at CF at 60 dB SPL re 20 microPa; 39% of the 44 units exhibited highly regular discharges (mean CV less than 0.35). During the onset (2-14.9 ms) time window, 77% (of 53 units with sufficient number of spikes for CV analysis) of the units had mean CVs less than 0.5, and 55% were less than 0.35. 3. In our sample of 87 DCN pause-build units, 59% had spontaneous rates (SR) greater than 15 spikes/s. The pause-build units of the present sample were distributed across four different EI-area types: III (51%), I/III (25%), II (15%), or IV (9%). In the 20- to 39.9-ms time window, the pause-build units with mean CVs less than 0.35 were exclusively of types III and I/III. All of the above EI-area types were represented in the lowest CV group for the 2- to 14.9-ms window. 4. The mean ISIs of DCN pause-build units typically showed a decrease during the first 20-25 ms of the response to 50-ms CF tone bursts, and stable mean ISIs in the latter half, when off-discharges were absent. In the presence of off-discharges, the mean ISIs decreased further in the last 5-10 ms of the response.(ABSTRACT TRUNCATED AT 400 WORDS)
摘要
  1. 我们研究了去大脑未麻醉猫的背侧耳蜗核(DCN)中单位放电的峰间期(ISI)的均值和标准差(SD)以及ISI的变异系数(CV,ISI的SD与ISI均值的比值)随时间的变化,以研究单位放电的规律性。通过使用刺激后时间直方图(PSTH)和兴奋 - 抑制面积(EI - area)方案对这些单位进行了特征描述。我们展示了本研究中记录的87个DCN暂停 - 增强型单位的系统检查结果。此外,我们还展示了DCN斩波亚型的示例。2. 本研究的一个主要发现是,本样本中的大多数暂停 - 增强型单位在特征频率(CF)下对短(50毫秒)纯音脉冲的反应表现出规律放电,CV小于0.5表明了这一点。在20至39.9毫秒的时间窗口内,对于60分贝声压级(相对于20微帕)的CF下50毫秒纯音脉冲,大部分暂停 - 增强型单位(用于CV分析的44个单位中有80%)的平均CV小于0.5;44个单位中有39%表现出高度规律的放电(平均CV小于0.35)。在起始(2至14.9毫秒)时间窗口内,(用于CV分析的53个单位中有)77%的单位平均CV小于0.5,55%小于0.35。3. 在我们的87个DCN暂停 - 增强型单位样本中,59%的自发发放率(SR)大于15次/秒。本样本中的暂停 - 增强型单位分布在四种不同的EI - area类型中:III型(51%)、I/III型(25%)、II型(15%)或IV型(9%)。在20至39.9毫秒的时间窗口内,平均CV小于0.35的暂停 - 增强型单位仅为III型和I/III型。在2至14.9毫秒窗口的最低CV组中,上述所有EI - area类型均有代表。4. DCN暂停 - 增强型单位的平均ISI通常在对50毫秒CF纯音脉冲反应的前20 - 25毫秒内下降,在后半段(无后续放电时)平均ISI保持稳定。在有后续放电的情况下,反应的最后5 - 10毫秒内平均ISI会进一步下降。(摘要截断于400字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验