Suppr超能文献

通过气压式全身体积描记法对健康犬的呼吸功能进行评估。

Evaluation of respiratory function by barometric whole-body plethysmography in healthy dogs.

作者信息

Talavera Jesús, Kirschvink Nathalie, Schuller Simone, Garrérès Alain Le, Gustin Pascal, Detilleux Johanne, Clercx Cécile

机构信息

Department of Animal Medicine and Surgery, University of Murcia, Spain.

出版信息

Vet J. 2006 Jul;172(1):67-77. doi: 10.1016/j.tvjl.2005.04.019. Epub 2005 Jul 5.

Abstract

The objective of the present study was to assess the validity of barometric whole-body plethysmography (BWBP), to establish reference values, and to standardise a bronchoprovocative test to investigate airway responsiveness using BWBP in healthy dogs. BWBP measurements were obtained from six healthy beagle dogs using different protocols: (1) during three consecutive periods (3.5min each) in two morning and two evening sessions; (2) before and after administration of two protocols of sedation; (3) before and after nebulisation of saline and increasing concentrations of carbachol and histamine both in conscious dogs and in dogs under both protocols of sedation. Enhanced pause (PENH) was used as index of bronchoconstriction. Basal BWBP measurements were also obtained in 22 healthy dogs of different breeds, age and weight. No significant influence of either time spent in the chamber or daytime was found for most respiratory variables but a significant dog effect was detected for most variables. A significant body weight effect was found on tidal volume and peak flow values (P<0.05). Response to carbachol was not reproducible and always associated with side effects. Nebulisation of histamine induced a significant increase in respiratory rate, peak expiratory flow, peak expiratory flow/peak inspiratory flow ratio and PENH (P<0.05). The response was reproduced in each dog at different concentrations of histamine. Sedation with acepromazine+buprenorphine had little influence on basal measurements and did not change the results of histamine challenge. It was concluded that BWBP is a safe, non invasive and reliable technique of investigation of lung function in dogs which provides new opportunities to characterise respiratory status, to evaluate airway hyperresponsiveness and to assess therapeutic interventions.

摘要

本研究的目的是评估气压式全身体积描记法(BWBP)的有效性,建立参考值,并标准化一项支气管激发试验,以使用BWBP研究健康犬的气道反应性。使用不同方案从六只健康的比格犬获取BWBP测量值:(1)在两个上午和两个晚上的时段中,连续三个时期(每个时期3.5分钟);(2)在给予两种镇静方案之前和之后;(3)在清醒犬以及处于两种镇静方案下的犬中,在雾化生理盐水以及增加卡巴胆碱和组胺浓度之前和之后。增强暂停(PENH)用作支气管收缩的指标。还在22只不同品种、年龄和体重的健康犬中获取了基础BWBP测量值。对于大多数呼吸变量,未发现待在舱内的时间或白天时间有显著影响,但对于大多数变量检测到显著的犬效应。发现体重对潮气量和峰值流量值有显著影响(P<0.05)。对卡巴胆碱的反应不可重复,且总是伴有副作用。组胺雾化导致呼吸频率、呼气峰值流量、呼气峰值流量/吸气峰值流量比值和PENH显著增加(P<0.05)。在每只犬中,不同浓度的组胺均可重现该反应。用乙酰丙嗪+丁丙诺啡镇静对基础测量影响很小,并且未改变组胺激发试验的结果。得出的结论是,BWBP是一种安全、无创且可靠的犬肺功能检测技术,它为表征呼吸状态、评估气道高反应性和评估治疗干预提供了新机会。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验