Hartwein J
Univ.-HNO-Klinik Hamburg-Eppendorf.
HNO. 1992 Apr;40(4):128-32.
We investigated the influence of varying compliance of the tympanic membrane on the sound pressure level of the human ear canal using a model with adjustable compliance. Decrease of compliance augments the sound pressure close to the tympanic membrane due to the increase of reflected sound pressure. This augmentation occurs in a narrow frequency area near the maximum resonance frequency and reaches 6 dB (SPL). These experimental data correlate well with clinical investigations in patients with middle ear effusion before and after operation and in patients performing the Valsalva manoeuvre.