Weber Bernard
Methods Mol Biol. 2005;304:245-55. doi: 10.1385/1-59259-907-9:245.
New screening enzyme immunoassays, which permit the simultaneous detection of HIV antigens reduce the diagnostic window period between the time of immunodeficiency virus (HIV) infection and seroconversion. The VIDAS HIV DUO Ultra is an enzyme-linked fluorescent assay (ELFA) for the screening of HIV infection. It is performed with the fully automated VIDAS or mini-VIDAS instruments, which are so-called walk away systems. The detection limit is 3 pg of HIV-1 p24 Ag/mL serum. HIV antibody is detected with the same sensitivity as stand-alone third-generation antibody tests. The total incubation time is about 2 h. Results are calculated, interpreted, and printed by the VIDAS instrument. Usually, fourth-generation assays demand a special algorithm for the analysis of reactive samples. For the anti-HIV part of the assay, confirmation of reactivity should be done with an assay that lacks the p24-antigen detection module and when reactivity persists subsequently by immunoblot. For the p24-antigen part, confirmation of reactivity should be analyzed in an assay that lacks the anti-HIV detection part.
新型筛查酶免疫测定法可同时检测HIV抗原,缩短了免疫缺陷病毒(HIV)感染与血清转化之间的诊断窗口期。VIDAS HIV DUO Ultra是一种用于筛查HIV感染的酶联荧光测定法(ELFA)。它使用全自动VIDAS或mini-VIDAS仪器进行检测,这些仪器是所谓的无需人工干预的系统。检测限为每毫升血清3 pg HIV-1 p24抗原。检测HIV抗体的灵敏度与单独的第三代抗体检测相同。总孵育时间约为2小时。结果由VIDAS仪器计算、解读并打印。通常,第四代检测需要一种特殊算法来分析反应性样本。对于该检测的抗HIV部分,应使用缺乏p24抗原检测模块的检测方法来确认反应性,并且当反应性随后通过免疫印迹持续存在时也应进行确认。对于p24抗原部分,应在缺乏抗HIV检测部分的检测方法中分析反应性的确认情况。