Thiel John A, Suchet Ian B, Lortie Karine
Department of Obstetrics and Gynecology, Regina Qu'Appelle Health Region, Regina, Saskatchewan, Canada.
Fertil Steril. 2005 Aug;84(2):504-8. doi: 10.1016/j.fertnstert.2005.01.135.
To determine the accuracy of ultrasound in the assessment of proximal fallopian tube positioning of the Essure microinsert coil 3 months after postprocedure.
Prospective cohort study (Canadian Task Force classification II-2).
Reproductive-age women in a tertiary care hospital.
PATIENT(S): Reproductive-age women presenting with a request for permanent contraception.
INTERVENTION(S): Hysteroscopic sterilization with the Essure microinsert coil and conventional or volume-contrast three-dimensional (3D) ultrasound imaging 3 months after the procedure.
MAIN OUTCOME MEASURE(S): Coil position on ultrasound.
RESULT(S): Forty-eight of the 50 patients had successful placement of the Essure coils, and three patients required a second attempt on one tube. Conventional or volume-contrast (3D) ultrasound showed proper positioning of the coils within the proximal fallopian tube in 42 women (84%); five women (10%) required hysterosalpingogram to show appropriate positioning. Two patients (4%) required laparoscopic tubal sterilization, and one patient (2%) was lost to follow-up.
CONCLUSION(S): Transvaginal ultrasound is an acceptable method of confirming proper placement of the Essure microinsert coil within the proximal fallopian tube 3 months after the procedure.
确定超声评估术后3个月时Essure微插入线圈在输卵管近端位置的准确性。
前瞻性队列研究(加拿大工作组分类II-2)。
一家三级护理医院的育龄妇女。
提出永久性避孕要求的育龄妇女。
采用Essure微插入线圈进行宫腔镜绝育术,并在术后3个月进行传统或容积对比三维(3D)超声成像。
超声检查时线圈的位置。
50例患者中有48例成功放置了Essure线圈,3例患者有一根输卵管需要再次尝试放置。传统或容积对比(3D)超声显示42例(84%)女性的线圈在输卵管近端位置正确;5例(10%)女性需要子宫输卵管造影来显示合适的位置。2例(4%)患者需要腹腔镜输卵管绝育术,1例(2%)患者失访。
经阴道超声是确认术后3个月时Essure微插入线圈在输卵管近端正确放置的可接受方法。