The neutron irradiation facility developed at the McMaster University 3 MV Van de Graaff accelerator was employed to assess in vivo elemental content of aluminum and manganese in human hands. These measurements were carried out to monitor the long-term exposure of these potentially toxic trace elements through hand bone levels. The dose equivalent delivered to a patient during irradiation procedure is the limiting factor for IVNAA measurements. This article describes a method to estimate the average radiation dose equivalent delivered to the patient's hand during irradiation. The computational method described in this work augments the dose measurements carried out earlier [Arnold et al., 2002. Med. Phys. 29(11), 2718-2724]. This method employs the Monte Carlo simulation of hand irradiation facility using MCNP4B. Based on the estimated dose equivalents received by the patient hand, the proposed irradiation procedure for the IVNAA measurement of manganese in human hands [Arnold et al., 2002. Med. Phys. 29(11), 2718-2724] with normal (1 ppm) and elevated manganese content can be carried out with a reasonably low dose of 31 mSv to the hand. Sixty-three percent of the total dose equivalent is delivered by non-useful fast group (> 10 keV); the filtration of this neutron group from the beam will further decrease the dose equivalent to the patient's hand.
利用麦克马斯特大学3兆伏范德格拉夫加速器开发的中子辐照设施,对人体手部铝和锰的体内元素含量进行评估。进行这些测量是为了通过手部骨骼水平监测这些潜在有毒微量元素的长期暴露情况。辐照过程中传递给患者的剂量当量是中子活化分析测量的限制因素。本文描述了一种估算辐照期间传递给患者手部的平均辐射剂量当量的方法。这项工作中描述的计算方法改进了早期进行的剂量测量[阿诺德等人,2002年。《医学物理》29(11),2718 - 2724]。该方法使用MCNP4B对手部辐照设施进行蒙特卡罗模拟。根据患者手部接收的估计剂量当量,对于正常(1 ppm)和锰含量升高的人体手部锰的中子活化分析测量[阿诺德等人,2002年。《医学物理》29(11),2718 - 2724],可以以相当低的31毫希沃特剂量对手部进行提议的辐照程序。总剂量当量的63%由非有用快中子群(> 10 keV)传递;从束流中过滤掉这个中子群将进一步降低传递给患者手部的剂量当量。