Differential use of image enhancement techniques by experienced and inexperienced observers.

作者信息

Krupinski Elizabeth A, Roehrig Hans, Dallas William, Fan Jiahua

机构信息

Department of Radiology, University of Arizona, 1609 N. Warren Bldg 211 Rm 112, Tucson, AZ 85724, USA.

出版信息

J Digit Imaging. 2005 Dec;18(4):311-5. doi: 10.1007/s10278-005-7666-z.

Abstract

Full-field digital mammography (FFDM) systems are currently being used to acquire mammograms in digital format, but digital displays are less than ideal compared to traditional film-screen display. Certain physical properties of softcopy displays [e.g., modulation transfer function (MTF)] are less than optimal compared to film. We developed methods to compensate for some of these softcopy display deficiencies, based on careful physical characterization of the displays and image-processing software. A series of 100 FFDM and 60 digitized images was shown to six observers-half experienced (mammographers) and half inexperienced (radiology residents). The observers had to decide if a mass or microcalcification cluster was present and classify it as benign or malignant. A window could be activated that brought the image detail within the window to full resolution and corrected for the nonisotropic MTF of the Cathode Ray Tube (CRT) display. Experienced readers had better diagnostic performance and took less time to view the images. Experienced readers used window/level more than inexperienced readers, but inexperienced readers used magnification and the MTF compensation tool more often. Use of the magnification and the MTF tool increased reader decision confidence. Experienced and inexperienced readers use image-processing tools differently, with certain tools increasing reader confidence. Understanding how observers use image-processing tools may help in the development of better and more automated user interfaces.

摘要

相似文献

1
Differential use of image enhancement techniques by experienced and inexperienced observers.
J Digit Imaging. 2005 Dec;18(4):311-5. doi: 10.1007/s10278-005-7666-z.
3
5
Soft copy display requirements for digital mammography.
J Digit Imaging. 2003 Sep;16(3):292-305. doi: 10.1007/s10278-003-1659-6. Epub 2003 Dec 15.
10
Characterization of the effects of the FineView algorithm for full field digital mammography.
Phys Med Biol. 2012 Apr 7;57(7):1987-2003. doi: 10.1088/0031-9155/57/7/1987. Epub 2012 Mar 20.

引用本文的文献

1
Digital zoom of the full-field digital mammogram versus magnification mammography: a systematic review.
Eur Radiol. 2020 Aug;30(8):4223-4233. doi: 10.1007/s00330-020-06798-6. Epub 2020 Mar 28.
2
Assessment of using digital manipulation tools for diagnosing mandibular radiolucent lesions.
Dentomaxillofac Radiol. 2012 Mar;41(3):203-10. doi: 10.1259/dmfr/78567773. Epub 2011 Nov 24.
4
Optimization of exposure parameters in full field digital mammography.
Med Phys. 2008 Jun;35(6):2414-23. doi: 10.1118/1.2912177.
5
Thick slices from tomosynthesis data sets: phantom study for the evaluation of different algorithms.
J Digit Imaging. 2009 Oct;22(5):519-26. doi: 10.1007/s10278-007-9075-y. Epub 2007 Oct 23.

本文引用的文献

1
Use of a human visual system model to predict observer performance with CRT vs LCD display of images.
J Digit Imaging. 2004 Dec;17(4):258-63. doi: 10.1007/s10278-004-1016-4.
4
Soft copy versus hard copy reading in digital mammography.
J Digit Imaging. 2003 Dec;16(4):341-4. doi: 10.1007/s10278-003-1661-z. Epub 2004 Jan 30.
6
8
Contrast enhancement in dense breast images using the modulation transfer function.
Med Phys. 2002 Dec;29(12):2925-36. doi: 10.1118/1.1521119.
10
Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography.
Eur Radiol. 2002 Nov;12(11):2679-83. doi: 10.1007/s00330-002-1354-x. Epub 2002 Apr 19.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验