Suppr超能文献

Treatment planning consideration for prostate implants with the new linear RadioCoil 103Pd brachytherapy source.

作者信息

Meigooni Ali S, Awan Shahid B, Rachabatthula Venkata, Koona Rafiq A

机构信息

Department of Radiation Medicine, University of Kentucky Chandler Medical Center, 800 Rose Street, Lexington, Kentucky 40536-0084, USA.

出版信息

J Appl Clin Med Phys. 2005 Summer;6(3):23-36. doi: 10.1120/jacmp.v6i3.2097. Epub 2005 Aug 12.

Abstract

Recently, various linear source models, for example, 103Pd RadioCoil, have been introduced to overcome the shortcomings of traditional "seed" type interstitial prostate brachytherapy implants, such as migration and clumping of the seeds. However, the existing prostate treatment-planning systems have not been updated to perform dose calculation for implants with linear sources greater than 1.0 cm in length. In these investigations, two new models are developed for 3D dose calculation for a prostate implant with linear brachytherapy sources using the commercially available treatment-planning systems. The proposed models are referred to as the linear-segmented source (LSS) model and the point-segmented source (PSS) model. The calculated dose distributions obtained by these models for a single linear source have been validated by their comparison with the Monte Carlo-simulated data. Moreover, these models were used to calculate the dose distributions for a multilinear source prostate implant, and the results were compared to "seed" type implants. The results of these investigations show that the LSS model better approximates the linear sources than the PSS model. Moreover, these models have shown a better approximation of the dose distribution from a linear source for 0.5 cm source segments as compared to 1.0 cm source segments. However, for the points close to the longitudinal axis of the source located outside the region bounded by the active length, both models show differences of approximately +/-15%. These deficiencies are attributed to the limitations of the TG43 formalism for elongated sources.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/451f/5723496/5fc1e43d9a28/ACM2-6-023-g001.jpg

相似文献

1
Treatment planning consideration for prostate implants with the new linear RadioCoil 103Pd brachytherapy source.
J Appl Clin Med Phys. 2005 Summer;6(3):23-36. doi: 10.1120/jacmp.v6i3.2097. Epub 2005 Aug 12.
4
Brachytherapy dosimetry parameters calculated for a new 103Pd source.
Med Phys. 2004 Sep;31(9):2466-70. doi: 10.1118/1.1781552.
10
Dose escalation in permanent brachytherapy for prostate cancer: dosimetric and biological considerations.
Phys Med Biol. 2003 Sep 7;48(17):2753-65. doi: 10.1088/0031-9155/48/17/302.

引用本文的文献

1
An endoscopic ultrasonography-guided interstitial brachytherapy based special treatment-planning system for unresectable pancreatic cancer.
Oncotarget. 2017 Feb 27;8(45):79099-79110. doi: 10.18632/oncotarget.15763. eCollection 2017 Oct 3.
2
A directional Pd brachytherapy device: Dosimetric characterization and practical aspects for clinical use.
Brachytherapy. 2017 Mar-Apr;16(2):421-432. doi: 10.1016/j.brachy.2016.11.011. Epub 2016 Dec 28.
3
A comparison study on various low energy sources in interstitial prostate brachytherapy.
J Contemp Brachytherapy. 2016 Feb;8(1):74-81. doi: 10.5114/jcb.2016.57708. Epub 2016 Feb 5.
4
Cylindrical coordinate based TG-43U1 parameters for dose calculation around elongated brachytherapy sources.
J Appl Clin Med Phys. 2008 Apr 16;9(2):123-142. doi: 10.1120/jacmp.v9i2.2760.
5
TG-43U1 parameterization of elongated RadioCoil 103Pd brachytherapy sources.
J Appl Clin Med Phys. 2007 Jul 17;8(3):60-75. doi: 10.1120/jacmp.v8i3.2435.

本文引用的文献

2
The use of linked seeds eliminates lung embolization following permanent seed implantation for prostate cancer.
Int J Radiat Oncol Biol Phys. 2004 Jun 1;59(2):397-9. doi: 10.1016/j.ijrobp.2003.10.034.
5
Seed migration in prostate brachytherapy: a re-implant case report.
Br J Radiol. 2003 Dec;76(912):913-5. doi: 10.1259/bjr/14541259.
8
The effect of seed orientation deviations on the quality of 125I prostate implants.
Phys Med Biol. 2001 Nov;46(11):2785-800. doi: 10.1088/0031-9155/46/11/303.
10
Comparison of I-125 sources used for permanent interstitial implants.
Med Phys. 2001 Apr;28(4):671-82. doi: 10.1118/1.1359246.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验