Suppr超能文献

螺旋热凝器治疗早期子宫内膜异位症的安全性

Safety of the Helica Thermal Coagulator in treatment of early stage endometriosis.

作者信息

Hill N C W, El-Toukhy T, Chandakas S, Grigoriades T, Erian J

机构信息

Minimal Access Unit, Department of Obstetrics and Gynaecology, The Princess Royal University Hospital, Orpington, Kent, UK.

出版信息

J Obstet Gynaecol. 2005 Jan;25(1):52-4. doi: 10.1080/01443610400024906.

Abstract

The objective of this prospective study was to assess the safety and short-term outcome of the Helica Thermal Coagulator in the laparoscopic treatment of early stage endometriosis. Two hundred and fifty consecutive women with chronic pelvic pain and stage I and II endometriosis (r-AFS classification) were treated laparoscopically with the Helica Thermal Coagulator. No bladder, ureteric or bowel injuries occurred. None of the procedures was converted to laparotomy and there were no major peri-operative complications. The only complication was a vaginal perforation during dissection of the cul-de-sac in a patient with a vaginal vault endometriotic nodule. We conclude that the Helica Thermal Coagulator is a safe alternative for the treatment of mild to moderate endometriosis. Long-term efficacy studies are required to better assess the role of the device in laparoscopic management of endometriosis.

摘要

这项前瞻性研究的目的是评估螺旋热凝器在腹腔镜治疗早期子宫内膜异位症中的安全性和短期疗效。连续250例患有慢性盆腔疼痛且为I期和II期子宫内膜异位症(r-AFS分类)的女性接受了螺旋热凝器的腹腔镜治疗。未发生膀胱、输尿管或肠道损伤。所有手术均未转为开腹手术,也未出现重大围手术期并发症。唯一的并发症是一名患有阴道穹窿子宫内膜异位结节的患者在直肠子宫陷凹解剖时发生阴道穿孔。我们得出结论,螺旋热凝器是治疗轻至中度子宫内膜异位症的一种安全选择。需要进行长期疗效研究,以更好地评估该设备在腹腔镜治疗子宫内膜异位症中的作用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验