Suppr超能文献

牛膝关节软骨的特定部位超声反射特性及表层胶原蛋白含量

Site-specific ultrasound reflection properties and superficial collagen content of bovine knee articular cartilage.

作者信息

Laasanen Mikko S, Saarakkala Simo, Töyräs Juha, Rieppo Jarno, Jurvelin Jukka S

机构信息

Department of Clinical Physiology and Nuclear Medicine, Kuopio University Hospital and University of Kuopio, POB 1777, FIN-70211 Kuopio, Finland.

出版信息

Phys Med Biol. 2005 Jul 21;50(14):3221-33. doi: 10.1088/0031-9155/50/14/002. Epub 2005 Jun 28.

Abstract

Previous quantitative 2D-ultrasound imaging studies have demonstrated that the ultrasound reflection measurement of articular cartilage surface sensitively detects degradation of the collagen network, whereas digestion of cartilage proteoglycans has no significant effect on the ultrasound reflection. In this study, the first aim was to characterize the ability of quantitative 2D-ultrasound imaging to detect site-specific differences in ultrasound reflection and backscattering properties of cartilage surface and cartilage-bone interface at visually healthy bovine knee (n = 30). As a second aim, we studied factors controlling ultrasound reflection properties of an intact cartilage surface. The ultrasound reflection coefficient was determined in time (R) and frequency domains (IRC) at medial femoral condyle, lateral patello-femoral groove, medial tibial plateau and patella using a 20 MHz ultrasound imaging instrument. Furthermore, cartilage surface roughness was quantified by calculating the ultrasound roughness index (URI). The superficial collagen content of the cartilage was determined using a FT-IRIS-technique. A significant site-dependent variation was shown in cartilage thickness, ultrasound reflection parameters, URI and superficial collagen content. As compared to R and IRC, URI was a more sensitive parameter in detecting differences between the measurement sites. Ultrasound reflection parameters were not significantly related to superficial collagen content, whereas the correlation between R and URI was high. Ultrasound reflection at the cartilage-bone interface showed insignificant site-dependent variation. The current results suggest that ultrasound reflection from the intact cartilage surface is mainly dependent on the cartilage surface roughness and the collagen content has a less significant role.

摘要

以往的定量二维超声成像研究表明,关节软骨表面的超声反射测量能够灵敏地检测到胶原网络的降解,而软骨蛋白聚糖的消化对超声反射没有显著影响。在本研究中,第一个目的是在视觉上健康的牛膝关节(n = 30)中,表征定量二维超声成像检测软骨表面和软骨-骨界面超声反射及背向散射特性的部位特异性差异的能力。作为第二个目的,我们研究了控制完整软骨表面超声反射特性的因素。使用20 MHz超声成像仪,在股骨内侧髁、外侧髌股沟、胫骨内侧平台和髌骨处,在时域(R)和频域(IRC)中测定超声反射系数。此外,通过计算超声粗糙度指数(URI)对软骨表面粗糙度进行量化。使用傅里叶变换红外成像光谱技术(FT-IRIS)测定软骨的表面胶原含量。结果显示,软骨厚度、超声反射参数、URI和表面胶原含量存在显著的部位依赖性差异。与R和IRC相比,URI在检测测量部位之间的差异时是一个更敏感的参数。超声反射参数与表面胶原含量无显著相关性,而R与URI之间的相关性较高。软骨-骨界面处的超声反射显示出不显著的部位依赖性差异。目前的结果表明,完整软骨表面的超声反射主要取决于软骨表面粗糙度,而胶原含量的作用较小。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验