Suppr超能文献

用于在大鼠模型中定量抗血管生成治疗中肿瘤灌注的功能CT

Functional CT for quantifying tumor perfusion in antiangiogenic therapy in a rat model.

作者信息

Kan Zuxing, Phongkitkarun Sith, Kobayashi Satoshi, Tang Yi, Ellis Lee M, Lee Ting Y, Charnsangavej Chusilp

机构信息

Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX 77030, USA.

出版信息

Radiology. 2005 Oct;237(1):151-8. doi: 10.1148/radiol.2363041293.

Abstract

PURPOSE

To determine the histologic basis of perfusion parameters measured at functional computed tomography (CT) and to examine the relationship between changes in perfusion and changes in histologic parameters after antiangiogenic therapy in a rat model.

MATERIALS AND METHODS

This study had institutional animal care and use committee approval. Among 20 Fischer rats with implanted FN13762 tumors in the liver, 10 were treated with SU5416, a tyrosine kinase inhibitor of vascular endothelial growth factor receptor, and 10 were treated with the diluent only as control rats. Six rats chosen at random from each group underwent functional CT for the measurement of tumor blood flow, blood volume, mean transit time, and permeability-surface area product. Tumor tissue slides corresponding to functional CT sections were examined to measure tumor microvascular density, number of luminal vessels, vascular perimeter, and vascular area. Two-tailed Student t testing was used to determine differences in growth, numbers of metastases to major organs, vascularity, and perfusion between SU5416-treated and control tumors. Pearson correlation coefficients were used to investigate relationships between vascular parameters.

RESULTS

Mean tumor volume and number of metastases, respectively, were lower in SU5416-treated rats than in control rats (1580 mm3 +/- 830 [standard deviation] vs 2330 mm3 +/- 960 and 22.4 +/- 11.0 vs 35.2 +/- 17.3); however, these differences were not significant (P = .084 and P = .079). Mean tumor microvascular density was significantly lower in SU5416-treated rats than in control rats (6.4 vessels per field +/- 4.6 vs 17.2 vessels per field +/- 7.5, P < .001); however, vessel perimeter and vessel area, respectively, were significantly larger in treated rats than in control rats (470 microm per field +/- 320 vs 360 microm per field +/- 270, P = .02; and 4010 microm2 per field +/- 2990 vs 2230 microm2 per field +/- 1750, P = .001). Significant correlations were observed between microvascular density and vessel perimeter and area (r = 0.59 and r = 0.25, respectively; P < .01 for both) in SU5416-treated tumors but not control tumors. Blood flow, blood volume, and permeability-surface area product at functional CT were significantly higher in SU5416-treated tumors than in control tumors (P < .001 for all).

CONCLUSION

These results validate the idea that functional CT can help quantify the perfusion function of mature vessels but not changes in microvessel density in antiangiogenic therapy.

摘要

目的

确定在功能计算机断层扫描(CT)中测量的灌注参数的组织学基础,并在大鼠模型中研究抗血管生成治疗后灌注变化与组织学参数变化之间的关系。

材料与方法

本研究获得了机构动物护理和使用委员会的批准。在20只肝脏植入FN13762肿瘤的Fischer大鼠中,10只接受血管内皮生长因子受体酪氨酸激酶抑制剂SU5416治疗,10只仅接受稀释剂治疗作为对照大鼠。从每组中随机选择6只大鼠进行功能CT检查,以测量肿瘤血流量、血容量、平均通过时间和通透表面积乘积。检查与功能CT切片相对应的肿瘤组织切片,以测量肿瘤微血管密度、管腔血管数量、血管周长和血管面积。采用双尾Student t检验来确定SU5416治疗组和对照组肿瘤在生长、主要器官转移数量、血管生成和灌注方面的差异。使用Pearson相关系数来研究血管参数之间的关系。

结果

SU5416治疗组大鼠的平均肿瘤体积和转移数量分别低于对照组大鼠(1580 mm3±830[标准差]对2330 mm3±960以及22.4±11.0对35.2±17.3);然而,这些差异不显著(P = 0.084和P = 0.079)。SU5416治疗组大鼠的平均肿瘤微血管密度显著低于对照组大鼠(每视野6.4条血管±4.6对每视野17.2条血管±7.5,P < 0.001);然而,治疗组大鼠的血管周长和血管面积分别显著大于对照组大鼠(每视野4测0μm±320对每视野360μm±270,P = 0.02;以及每视野4010μm2±2990对每视野2230μm2±1750,P = 0.001)。在SU5416治疗的肿瘤中观察到微血管密度与血管周长和面积之间存在显著相关性(分别为r = 0.59和r = 0.25;两者P < 0.01),而在对照肿瘤中未观察到。功能CT检查时,SU5416治疗的肿瘤的血流量、血容量和通透表面积乘积显著高于对照肿瘤(所有P < 0.001)。

结论

这些结果证实了功能CT有助于量化成熟血管的灌注功能,但不能量化抗血管生成治疗中微血管密度变化的观点。