Kao C H, Lin W Y, Wang S J
Department of Nuclear Medicine, Taichung Vaterans General Hospital, Taiwan, Republic of China.
Gaoxiong Yi Xue Ke Xue Za Zhi. 1992 May;8(5):272-6.
A total of 15 patients who underwent total neck exploration for hyperparathyroidism were studied with four different imaging modalities: (a) Tl-201/Tc-99m subtraction scan (SS), (b) ultrasonography (US), (c) computed tomography (CT) and (d) magnetic resonance imaging (MRI). Accuracy for locating enlarged parathyroid(s) was 60.0% by SS, 60.0% by US, 33.3% by CT and 71.4% by MRI. Our results suggested that at present none of the imaging modalities was adequate on its own to locate all enlarged parathyroid gland(s) in patients with hyperparathyroidism.
共有15例因甲状旁腺功能亢进接受全颈部探查的患者接受了四种不同成像方式的检查:(a)铊-201/锝-99m减影扫描(SS),(b)超声检查(US),(c)计算机断层扫描(CT)和(d)磁共振成像(MRI)。SS定位增大甲状旁腺的准确率为60.0%,US为60.0%,CT为33.3%,MRI为71.4%。我们的结果表明,目前没有一种成像方式能单独准确找出所有甲状旁腺功能亢进患者增大的甲状旁腺。