表面光洁度对牙科复合修复材料压痕模量和硬度的影响。

Effects of surface finish on indentation modulus and hardness of dental composite restoratives.

作者信息

Chung S M, Yap A U J

机构信息

Department of Restorative Dentistry, Faculty of Dentistry, National University of Singapore, 5 Lower Kent Ridge Road, Singapore 119074, Singapore.

出版信息

Dent Mater. 2005 Nov;21(11):1008-16. doi: 10.1016/j.dental.2004.11.006. Epub 2005 Oct 3.

Abstract

OBJECTIVES

The depth-sensing micro-indentation testing was recently introduced for the characterization of dental composites. One of the critical issues raised was the possible influence of surface finish on material properties. The aim of this study was to investigate the effects of surface finish on the indentation modulus and micro-hardness of resin-based dental composite materials.

METHODS

The materials used included minifill (Z100, 3M ESPE), microfill (A110, 3M ESPE) and poly-acid modified (F2000, 3M ESPE) composites. The specimens were polished successively using SiC grinding papers of different grit size and diamond suspensions to achieve varying surface roughness. The arithmetic mean of the roughness (R(a)) was measured using profilometry. In the depth-sensing micro-indentation test, specimens (n=7) were indented to 10N with Vickers indenter and the load-displacement (P-h) data was obtained using a universal testing system. The indentation modulus (E(in)) and hardness (H) were then computed using the developed analytical solutions. Data was analyzed using ANOVA/post-hoc Scheffe's test at significance level 0.05.

RESULTS

The polished specimens had surface roughness ranging from 0.02 to 0.81 microm. The roughness of F2000 was significantly higher than A110 and Z100. The E(in) and H for Z100 ranged from 14.02 to 14.83GPa and 1.18 to 1.27 GPa, respectively. E(in) for F2000 and A110 ranged from 12.25 to 13.82 GPa and 5.26 to 5.52 GPa and hardness ranged from 0.89 to 0.98 GPa and 0.52 to 0.55 GPa, respectively.

SIGNIFICANCE

The indentation modulus and hardness of dental composite restoratives were independent of the surface finish provided indenter penetration is sufficiently deep (h(max)/R(a)>30).

摘要

目的

深度传感微压痕测试最近被引入用于牙科复合材料的表征。其中一个引发的关键问题是表面光洁度对材料性能的可能影响。本研究的目的是调查表面光洁度对树脂基牙科复合材料的压痕模量和显微硬度的影响。

方法

使用的材料包括微填料(Z100,3M ESPE)、微填料(A110,3M ESPE)和聚酸改性(F2000,3M ESPE)复合材料。使用不同粒度的碳化硅砂纸和金刚石悬浮液依次对试样进行抛光,以获得不同的表面粗糙度。使用轮廓仪测量粗糙度的算术平均值(R(a))。在深度传感微压痕测试中,用维氏压头将试样(n=7)压入至10N,并使用万能测试系统获得载荷-位移(P-h)数据。然后使用开发的解析解计算压痕模量(E(in))和硬度(H)。使用ANOVA/事后Scheffe检验在显著性水平0.05下分析数据。

结果

抛光后的试样表面粗糙度范围为0.02至0.81微米。F2000的粗糙度明显高于A110和Z100。Z100的E(in)范围为14.02至14.83GPa,H范围为1.18至1.27GPa。F2000和A110的E(in)范围分别为12.25至13.82GPa和5.26至5.52GPa,硬度范围分别为0.89至0.98GPa和0.52至0.55GPa。

意义

如果压头穿透足够深(h(max)/R(a)>30),牙科复合修复材料的压痕模量和硬度与表面光洁度无关。