Suppr超能文献

用于评估瞬态现象的单心跳心脏标记

Single heartbeat cardiac tagging for the evaluation of transient phenomena.

作者信息

Herzka Daniel A, Derbyshire J Andrew, Kellman Peter, McVeigh Elliot R

机构信息

Department of Biomedical Engineering, Johns Hopkins University School of Medicine Baltimore, Maryland 20892-1061, USA.

出版信息

Magn Reson Med. 2005 Dec;54(6):1455-64. doi: 10.1002/mrm.20719.

Abstract

Many cardiac abnormalities are of a transient nature, creating a beat-to-beat variation in myocardial function. This work presents the cardiac imaging technique for the measurement of regional function during transient cardiac phenomena. All information necessary for the reconstruction of a cine loop is acquired within a single heartbeat, avoiding the temporal blurring introduced by segmented imaging due to the assumption of cardiac cycle periodicity. This method incorporates a gradient-optimized, high-efficiency EPI-SSFP sequence and TSENSE parallel imaging. For acquisitions with readout resolutions of 128,160, 192, and 256 points, the technique produced images with average temporal resolution of 35, 39, 43, and 52 ms and average spatial resolutions of 2.65, 2.12, 1.77, and 1.32 mm in the readout direction, respectively, and 2.88 and 2.08 mm in the phase encode direction for acceleration rates of 3 and 4, respectively. Local apparent strains in the single slice and measurements of ventricular end-systolic and end-diastolic areas were used as quantitative measures to validate the single heartbeat technique. To demonstrate the utility of the sequence, movie loops were acquired for multiple heartbeats in non-breath-held acquisitions as well as during a Valsalva maneuver. A heartbeat-interleaved acquisition allowed for the reconstruction of nonaccelerated images from R contiguous heartbeats. Images reconstructed from such data displayed tag blurring and reduced tag persistence due to motion and inter-heartbeat variability. Images acquired during the Valsalva maneuver demonstrated apparent beat-to-beat variability, visible both in the images and as changing strain patterns and ventricular volumes.

摘要

许多心脏异常具有短暂性,会导致心肌功能逐搏变化。这项工作介绍了一种心脏成像技术,用于测量短暂心脏现象期间的局部功能。重建电影环所需的所有信息都在一次心跳内获取,避免了由于假设心动周期周期性而通过分段成像引入的时间模糊。该方法采用了梯度优化的高效EPI-SSFP序列和TSENSE并行成像。对于读出分辨率为128、160、192和256点的采集,该技术分别在3倍和4倍加速率下,在读出方向上产生的图像平均时间分辨率为35、39、43和52毫秒,平均空间分辨率分别为2.65、2.12、1.77和1.32毫米,在相位编码方向上分别为2.88和2.08毫米。单切片中的局部表观应变以及心室收缩末期和舒张末期面积的测量被用作定量指标来验证单心跳技术。为了证明该序列的实用性,在非屏气采集以及瓦尔萨尔瓦动作期间采集了多个心跳的电影环。心跳交错采集允许从R个连续心跳重建非加速图像。从这些数据重建的图像由于运动和心跳间变异性而显示出标记模糊和标记持久性降低。在瓦尔萨尔瓦动作期间采集的图像显示出明显的逐搏变异性,在图像中以及作为变化的应变模式和心室容积都可见。

相似文献

1
Single heartbeat cardiac tagging for the evaluation of transient phenomena.
Magn Reson Med. 2005 Dec;54(6):1455-64. doi: 10.1002/mrm.20719.
10
Strain measurement in the left ventricle during systole with deformable image registration.
Med Image Anal. 2009 Apr;13(2):354-61. doi: 10.1016/j.media.2008.07.004. Epub 2008 Sep 17.

本文引用的文献

1
Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals.
IEEE Trans Med Imaging. 1987;6(2):157-64. doi: 10.1109/TMI.1987.4307816.
2
Self-gated cardiac cine MRI.
Magn Reson Med. 2004 Jan;51(1):93-102. doi: 10.1002/mrm.10664.
3
Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD.
Magn Reson Med. 2003 Aug;50(2):315-21. doi: 10.1002/mrm.10504.
7
Is TrueFISP a gradient-echo or a spin-echo sequence?
Magn Reson Med. 2003 Feb;49(2):395-7. doi: 10.1002/mrm.10351.
8
Myocardial tagging with SSFP.
Magn Reson Med. 2003 Feb;49(2):329-40. doi: 10.1002/mrm.10361.
9
Triggered real-time MRI and cardiac applications.
Magn Reson Med. 2003 Jan;49(1):188-92. doi: 10.1002/mrm.10341.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验