第一跖背侧活动度临床测量指标的效标关联效度。
Criterion-related validity of a clinical measure of dorsal first ray mobility.
作者信息
Glasoe Ward Mylo, Getsoian Scott, Myers Matthew, Komnick Matthew, Kolkebeck Denny, Oswald Wolfgang, Liakos Photine
机构信息
Program in Physical Therapy, University of Minnesota, Minneapolis, MN 55455, USA.
出版信息
J Orthop Sports Phys Ther. 2005 Sep;35(9):589-93. doi: 10.2519/jospt.2005.35.9.589.
STUDY DESIGN
Test-retest methodological design using a sample of convenience.
OBJECTIVE
To determine the criterion-related validity and the reliability of measuring first ray mobility with a ruler.
BACKGROUND
Studies have questioned the accuracy of assessing first ray mobility by manual examination. Use of a ruler and adherence to strict guidelines in positioning of the patient may improve the measure. This study investigates the validity, and the intrarater and interrater reliability of measuring dorsal first ray mobility with a ruler while following recent recommendations to standardize the position of measurement. A valid and reliable mechanical device designed to measure first ray mobility was used as the validation criterion of measurement.
METHODS
Three clinicians performed ruler measurement of dorsal mobility on 14 subjects. A separate examiner measured dorsal mobility with the mechanical device. Intraclass correlation coefficients (ICCs) and standard error of measurements (SEMs) were computed to quantify the intrarater reliability of both testing procedures and the interrater reliability of the ruler measurement. ICCs of agreement were also computed to determine the concurrent validity of the ruler measurement for each clinician.
RESULTS
Mechanical device intrarater reliability ICC was 0.98 (SEM = 0.15 mm). Ruler intrarater ICCs were equal or less than -0.06 (SEMs = 1.1 mm); ruler interrater ICC was 0.05 (SEM = 1.2 mm). The ICCs of agreement between the mechanical device and ruler method ranged from -0.44 to 0.06.
CONCLUSION
The ruler method of testing demonstrates poor reliability and validity as a clinical measure.
研究设计
采用便利抽样的重测方法学设计。
目的
确定使用直尺测量第一跖骨活动度的效标关联效度和信度。
背景
研究对通过手法检查评估第一跖骨活动度的准确性提出了质疑。使用直尺并严格遵循患者体位摆放指南可能会提高测量的准确性。本研究在遵循近期测量位置标准化建议的同时,调查了使用直尺测量第一跖骨背侧活动度的效度、测量者内信度和测量者间信度。一种设计用于测量第一跖骨活动度的有效且可靠的机械装置被用作测量的验证标准。
方法
三名临床医生对14名受试者进行直尺测量第一跖骨背侧活动度。另一名检查者使用机械装置测量第一跖骨背侧活动度。计算组内相关系数(ICC)和测量标准误(SEM),以量化两种测试程序的测量者内信度以及直尺测量的测量者间信度。还计算了一致性ICC,以确定每位临床医生直尺测量的同时效度。
结果
机械装置测量者内信度ICC为0.98(SEM = 0.15毫米)。直尺测量者内ICC等于或小于-0.06(SEM = 1.1毫米);直尺测量者间ICC为0.05(SEM = 1.2毫米)。机械装置与直尺测量方法之间的一致性ICC范围为-0.44至0.06。
结论
作为一种临床测量方法,直尺测试方法显示出较差的信度和效度。