Nepomuceno Richard L, Boxer Wachler Brian S, Weissman Barry A
UCLA Department of Ophthalmology, Jules Stein Eye Institute, 100 Stein Plaza, Los Angeles, CA 90095, USA.
Cont Lens Anterior Eye. 2003 Dec;26(4):175-80. doi: 10.1016/S1367-0484(03)00049-3.
To demonstrate the feasibility of contact lens fitting in keratoconus patients with INTACS inserts.
A chart review was conducted of all patients with bilateral keratoconus who were treated with INTACS inserts on one eye and who were subsequently referred for contact lens fitting in a university based contact lens practice between April 2000 and April 2002. The study was a retrospective, non-comparative case series. The uncorrected and best spectacle corrected visual acuity (BSCVA) after INTACS implantation surgery, postoperative best contact lens-corrected visual acuity (BCLVA), number of diagnostic contact lenses used, number of contact lenses ordered within a 4-month follow-up period, contact lens complications encountered, final base curves, final lens powers, and final wearing times were determined.
Three keratoconic patients meeting the selection criteria were found through the chart review. Prior to surgery, all patients had uncorrected visual acuity (UCVA) of 2.0 logMAR (counting fingers). This improved to a mean of 0.81+/-0.25 logMAR (20/125-1) after surgery. Mean BSCVA also improved from 0.51+/-0.30 logMAR (20/60-2) to 0.30+/-0.16 logMAR (20/40). The mean postoperative best contact lens-corrected visual acuity was 0.02+/-0.10 logMAR (20/20-1). The number of diagnostic lenses ranged from 1 to 7. The numbers of contact lenses ordered during the 4-month follow up period ranged from 1 to 3. Two eyes were fitted with larger than usual lens designs made of rigid gas-permeable material and one eye was fitted with a toric soft lens. The final lens power ranged from +1.25 to -21.0D with a mean spherical equivalent of -7.46+/-11.89 D. Final wearing times ranged from 2.5 to 12.0h.
Fitting contact lenses on keratoconus patients who have INTACS inserts is feasible and has a role in augmenting their vision.
证明对植入INTACS植入片的圆锥角膜患者验配隐形眼镜的可行性。
对2000年4月至2002年4月期间在一所大学的隐形眼镜诊所接受治疗的所有双眼圆锥角膜患者进行病历回顾,这些患者一只眼睛植入了INTACS植入片,随后被转诊来验配隐形眼镜。该研究为回顾性、非对照病例系列研究。确定了INTACS植入手术后的未矫正视力和最佳矫正视力(BSCVA)、术后最佳隐形眼镜矫正视力(BCLVA)、使用的诊断性隐形眼镜数量、4个月随访期内订购的隐形眼镜数量、遇到的隐形眼镜并发症、最终基弧、最终镜片度数和最终佩戴时间。
通过病历回顾发现3例符合入选标准的圆锥角膜患者。手术前,所有患者的未矫正视力(UCVA)为2.0 logMAR(数指)。手术后平均提高到0.81±0.25 logMAR(20/125 - 1)。平均BSCVA也从0.51±0.30 logMAR(20/60 - 2)提高到0.30±0.16 logMAR(20/40)。术后最佳隐形眼镜矫正视力平均为0.02±0.10 logMAR(20/20 - 1)。诊断性镜片数量为1至7片。4个月随访期内订购的隐形眼镜数量为1至3片。两只眼睛验配了比通常更大的由硬性透气材料制成的镜片设计,一只眼睛验配了复曲面软性镜片。最终镜片度数范围为+1.25至 - 21.0D,平均球镜当量为 - 7.46±11.89D。最终佩戴时间为2.5至12.0小时。
对植入INTACS植入片的圆锥角膜患者验配隐形眼镜是可行的,并且在提高他们的视力方面有作用。