Akça Kivanç, Akkocaoğlu Murat, Cömert Ayhan, Tekdemir Ibrahim, Cehreli Murat Cavit
Department of Prosthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey.
Clin Oral Implants Res. 2005 Dec;16(6):715-22. doi: 10.1111/j.1600-0501.2005.01176.x.
To evaluate ex vivo bone tissue strains around maxillary implants supporting immediately loaded bar-retained overdentures.
Ninety degree two-element rosette strain gauges were bonded on the labial bone of four ITI dental implants placed in the maxillary anterior region of four completely edentulous maxilla of fresh human cadavers. The installation torque value (ITV) of each implant was measured by a custom-made torque wrench and resonance frequency analyses (RFAs) were undertaken. A bar-retained overdenture was fabricated for each cadaver, and two miniature load cells were integrated in the first molar region of the overdentures for controlled loading experiments. Strain measurements were performed at a sample rate of 10 kHz and under a maximum load of 100 N, simultaneously monitored from a computer connected to a data acquisition system. Finally, removal torque values (RTVs) of the implants were measured.
RFA values did not mirror ITVs, while RTVs of implants were slightly lower than the ITVs. Any correlation could not be obtained between RFA values and ITVs or RTVs. Maximum strains around loaded implants ranged between -100 and -550 microepsilon under 25-100 N. The axial and lateral strain values of posterior implants of both sides were higher than those of anterior implants under all loads (P<0.05).
Because occlusal forces in humans tend to decrease because of age-related factors, maximum strains around immediately loaded implants supporting maxillary overdentures fall within physiologic levels.
评估支持即刻负重杆卡式覆盖义齿的上颌种植体周围的离体骨组织应变。
将90度双元件应变片粘贴在4具新鲜人尸体全口无牙上颌骨前牙区植入的4颗ITI牙种植体的唇侧骨上。用定制扭矩扳手测量每个种植体的安装扭矩值(ITV),并进行共振频率分析(RFA)。为每具尸体制作一个杆卡式覆盖义齿,并在覆盖义齿的第一磨牙区集成两个微型测力传感器进行控制加载实验。应变测量以10kHz的采样率进行,最大负载为100N,同时通过连接到数据采集系统的计算机进行监测。最后,测量种植体的拆除扭矩值(RTV)。
RFA值与ITV不相符,而种植体的RTV略低于ITV。RFA值与ITV或RTV之间未发现任何相关性。在25-100N负载下,负重种植体周围的最大应变在-100至-550微应变之间。在所有负载下,两侧后牙种植体的轴向和侧向应变值均高于前牙种植体(P<0.05)。
由于与年龄相关的因素,人类的咬合力往往会降低,因此支持上颌覆盖义齿的即刻负重种植体周围的最大应变处于生理水平。