可见光漫反射分光光度法:组织模型中四种不同方法的比较

Diffuse reflectance spectrophotometry with visible light: comparison of four different methods in a tissue phantom.

作者信息

Gade John, Palmqvist Dorte, Plomgård Peter, Greisen Gorm

机构信息

Department of Cardiothoracic Surgery RT, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.

出版信息

Phys Med Biol. 2006 Jan 7;51(1):121-36. doi: 10.1088/0031-9155/51/1/009. Epub 2005 Dec 15.

Abstract

The purpose of the study was to compare algorithms of four methods (plus two modifications) for spectrophotometric haemoglobin saturation measurements. Comparison was made in tissue phantoms basically consisting of a phosphate buffer, Intralipid and blood, allowing samples to be taken for reference measurements. Three experimental series were made. In experiment A (eight phantoms) we used the Knoefel method and measured specific extinction coefficients with a reflection spectrophotometer. In experiment B (six phantoms) the fully oxygenated phantoms were gradually deoxygenated with baker's yeast, and simultaneous measurements were made with our spectrophotometer and with a reference oxymeter (ABL-605) in 3 min intervals. For each spectrophotometric measurement haemoglobin saturation was calculated with all algorithms and modifications, and compared with reference. In experiment C (11 phantoms) we evaluated the ability of a modification of the Knoefel method to measure haemoglobin concentration in absolute quantities using extinction coefficients from experiment A.Results. Experiment A: with the Knoefel method extinction coefficients (+/-SD) for oxyhaemoglobin at 553.04 and 573.75 nm were 1.117 (+/-0.0396) ODmM(-1) and 1.680 (+/- 0.0815) ODmM(-1), respectively, and for deoxyhaemoglobin 1.205 (+/- 0.0514) ODmM(-1) and 0.953 (+/-0.0487) ODmM(-1), respectively. Experiment B: high correlation with the reference was found in all methods (r = 0.94-0.97). However, agreement varied from evidently wrong in method 3 and the original method 4 (e.g. saturation above 160%) to high agreement in method 2 as well as the modifications of methods 1 and 4, where oxygen dissociation curves were close to the reference method. Experiment C: with the modified Knoefel method the mean haemoglobin concentration difference from reference was 8.3% and the correlation was high (r = 0.91). We conclude that method 2 and the modifications of 1 and 4 were superior to the others, but depended on known values in the same or similar phantoms. The original method 1 was independent of results from the tissue phantoms, but agreement was slightly poorer. Method 3 and the original method 4 could not be recommended. The ability of the modified method 1 to measure haemoglobin concentration is promising, but needs further development.

摘要

本研究的目的是比较四种方法(外加两种改良方法)用于分光光度法测量血红蛋白饱和度的算法。比较是在基本由磷酸盐缓冲液、英脱利匹特和血液组成的组织模型中进行的,以便采集样本进行参考测量。进行了三个实验系列。在实验A(八个模型)中,我们使用克内费尔方法,并用反射分光光度计测量特定消光系数。在实验B(六个模型)中,用面包酵母使完全氧合的模型逐渐脱氧,每隔3分钟用我们的分光光度计和参考血氧计(ABL - 605)同时进行测量。对于每次分光光度测量,用所有算法和改良方法计算血红蛋白饱和度,并与参考值进行比较。在实验C(11个模型)中,我们评估了克内费尔方法的一种改良方法使用实验A中的消光系数来绝对测量血红蛋白浓度的能力。结果。实验A:采用克内费尔方法,在553.04和573.75 nm处氧合血红蛋白的消光系数(±标准差)分别为1.117(±0.0396)ODmM⁻¹和1.680(±0.0815)ODmM⁻¹,脱氧血红蛋白的消光系数分别为1.205(±0.0514)ODmM⁻¹和0.953(±0.0487)ODmM⁻¹。实验B:在所有方法中均发现与参考值高度相关(r = 0.94 - 0.97)。然而,一致性有所不同,方法3和原始方法4明显错误(例如饱和度高于160%),而方法2以及方法1和4的改良方法一致性较高,其氧解离曲线接近参考方法。实验C:采用改良的克内费尔方法,与参考值相比血红蛋白浓度的平均差异为8.3%,相关性较高(r = 0.91)。我们得出结论,方法2以及方法1和4的改良方法优于其他方法,但依赖于相同或相似模型中的已知值。原始方法1不依赖于组织模型的结果,但一致性稍差。方法3和原始方法4不推荐使用。改良方法1测量血红蛋白浓度的能力很有前景,但需要进一步改进。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验